Similar outcomes to primary total knee arthroplasty achievable for aseptic revision using the same primary posterior-stabilised prosthesis at a mean follow-up of 49 months.

Knee Surg Sports Traumatol Arthrosc

Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 103 Grande Rue de la Croix Rousse, 69004, Lyon, France.

Published: August 2022

Purpose: The aim of the study was to compare clinical and radiological outcomes between primary and aseptic revision TKAs using the same posterior-stabilised (PS) prosthesis. The authors hypothesised similar outcomes between both groups for selected patients.

Methods: This retrospective, case-control study assessed 36 patients who underwent aseptic revision TKA compared to a match group of 72 primary TKA. Both groups had the same PS design implant (ANATOMIC®, Amplitude, Valence, France). The International Knee Society (IKS) score, radiological outcomes (postoperative alignment, patellar tilt and radiolucent lines), re-intervention and revision rate were compared between the two groups with a minimum follow-up of 3 years.

Results: The final study cohort included 29 patients and 63 patients respectively in the revision and primary group, with a mean follow-up of 49.1 months (range 36.1-69). Postoperatively, there was no significant difference in IKS scores between the two groups [169.8 for the revision group and 179.6 for the primary group (p = 0.09)]. No statistical difference was observed for post-operative satisfaction 86.2% versus 92.1% (p = 0.46). Between the two groups, there was no difference in mean radiological assessment, including radiolucent lines (p = 0.7). There was no significant difference for overall implant survivorship 96.5% versus 100% (p = 0.13) at 36 months.

Conclusion: Similar clinical, radiological and survivorship outcomes were found between rTKA and primary TKA groups using the same PS level of constraint in patients undergoing revision surgery for aseptic indications at 3-year follow-up. Use of PS implants in rTKA for the correct indication suggests this to be a safe approach at least in the medium term.

Level Of Evidence: IV, retrospective case-control study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-021-06716-3DOI Listing

Publication Analysis

Top Keywords

aseptic revision
12
outcomes primary
8
revision primary
8
posterior-stabilised prosthesis
8
clinical radiological
8
radiological outcomes
8
retrospective case-control
8
case-control study
8
primary tka
8
tka groups
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!