Outcome of proximal femur shaft fractures in school going children treated with locking compression plates.

Pak J Med Sci

Dr. Naeemullah, FCPS. Department of Orthopaedics & Traumatology, Lady Reading Hospital, Peshawar, Pakistan.

Published: January 2021

Objectives: To determine the clinical and radiological outcome of proximal femur shaft fractures in school going children treated with locking compression plates (LCP).

Methods: This descriptive study was conducted in Orthopaedic Division Lady Ready Reading Hospital Peshawar from 25 June 2018 to 25 September 2020. Children of either gender and age 6 to 12 years old with subtrochanteric and proximal one third femur factures fulfilling the inclusion criteria were enrolled in this study. Open reduction and internal fixation with 4.5 mm narrow locking compression plates (LCP) were done in all. Post operative clinical outcome was evaluated by using Flynn scoring system and graded as excellent, satisfactory and poo results. Radiological assessment of fracture union was done through anteroposterior (AP) and lateral X-ray radiographs.

Results: A total of 60 children with mean age 9.01±1.61 SD (range 6 to 12 years) were included in our study. Oblique fractures were present in 23(38.3%) children, spiral in 20(33.3%), transverse in 11(18.3%) and comminuted in 6 (10%) children. The radiological union time was 13.3±1.2 weeks (range 9.4 to 18 weeks). Majority (88.3%, n=53) of children had excellent clinical outcome according to Flynn's scoring system while satisfactory outcome was noted in 7(11.6%) children. No cases of delayed union, mal union, nonunion and implant failure was reported.

Conclusion: The results of our study indicated that proximal femoral shaft fractures in school going children treated with locking compression plates had excellent clinical and radiological outcome. We therefore recommend locking compression plate as the implant of choice to fix proximal femoral shaft fractures in school going children.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8377903PMC
http://dx.doi.org/10.12669/pjms.37.5.3938DOI Listing

Publication Analysis

Top Keywords

locking compression
20
shaft fractures
16
fractures school
16
school going
16
going children
16
compression plates
16
children treated
12
treated locking
12
children
10
outcome proximal
8

Similar Publications

A coherent optical frequency comb (OFC) with suppressed linewidth is demonstrated based on the spectral broadening of a directly modulated semiconductor microcavity laser with self-injection locking. Due to the high electro-optical response, the directly modulated microcavity laser provides a 10-GHz-spaced seeding OFC with 9 comb teeth in a 10 dB flatness window. Besides, an optical feedback fiber loop with two sub-loops is introduced to reduce the linewidth of the microlaser and suppress the undesired longitudinal modes.

View Article and Find Full Text PDF

We demonstrated what is believed to be the first 1.2 GHz nonlinear polarization rotation stretched-pulse mode-locked Yb:fiber laser with a compact design and innovative components. With a compact Faraday rotation angle has been used in NPR mode-locked lasers, and we find that incomplete isolation of backward-propagating light does not hinder self-starting.

View Article and Find Full Text PDF

Locking plates have a rapidly growing process especially in the past decades and results are satisfactory especially in the osteoporotic bones compared to non-locking compression plates. There are many forms of failure in the fracture fixation of locking plates, and screw pull-out is one of the main failure reasons. In this study, we aim to investigate pull-out failure in locking plates using locking spongious screws.

View Article and Find Full Text PDF

Objective:  To determine the effect of locking head inserts (LHI) on plate strain, stiffness, and deformation when applied to a 3.5-mm broad locking compression plate (LCP) in an open fracture-gap model.

Study Design:  Six, 13-hole, 3.

View Article and Find Full Text PDF

Mandibular Reconstruction With a Patient-Specific Implant Following Surgical Excision of an Acanthomatous Ameloblastoma in a Dog.

J Vet Dent

January 2025

Department of Dentistry, Oral and Maxillo-facial Surgery, Eastcott Veterinary Referrals, Part of Linnaeus Group, Swindon, UK.

Canine acanthomatous ameloblastoma (CAA) is an invasive benign epithelial odontogenic tumour most commonly affecting the mandible of large breed dogs. To the author's knowledge, this report describes the first computer-aided design patient-specific implant (PSI) that has been placed for a critical sized bone defect in mandibular reconstruction of a dog in the UK. The aim was to restore mandibular stability using a regenerative approach combining a titanium locking plate and compression-resistant matrix infused with recombinant human bone morphogenetic protein-2 (rhBMP-2) to bridge the 85 mm mandibular defect created by a segmental mandibulectomy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!