Improving reproducibility in synchrotron tomography using implementation-adapted filters.

J Synchrotron Radiat

Computational Imaging, Centrum Wiskunde and Informatica, Amsterdam, The Netherlands.

Published: September 2021

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8415339PMC
http://dx.doi.org/10.1107/S1600577521007153DOI Listing

Publication Analysis

Top Keywords

synchrotron tomography
8
implementation-adapted filters
8
improving reproducibility
4
reproducibility synchrotron
4
tomography implementation-adapted
4
filters reconstructing
4
reconstructing large
4
large tomographic
4
tomographic datasets
4
datasets fast
4

Similar Publications

Imaging the entire cardiomyocyte network in entire small animal hearts at single cell resolution is a formidable challenge. Optical microscopy provides sufficient contrast and resolution in 2d, however fails to deliver non-destructive 3d reconstructions with isotropic resolution. It requires several invasive preparation steps, which introduce structural artefacts, namely dehydration, physical slicing and staining, or for the case of light sheet microscopy also clearing of the tissue.

View Article and Find Full Text PDF

The human placenta exhibits a complex three-dimensional (3D) structure with a interpenetrating vascular tree and large internal interfacial area. In a unique and yet insufficiently explored way, this parenchymal structure enables its multiple functions as a respiratory, renal, and gastrointestinal multiorgan. The histopathological states are highly correlated with complications and health issues of mother, and fetus or newborn.

View Article and Find Full Text PDF

Phase-contrast micro-tomography ([Formula: see text]CT) with synchrotron radiation can aid in the differentiation of subtle density variations in weakly absorbing soft tissue specimens. Modulation-based imaging (MBI) extracts phase information from the distortion of reference patterns, generated by periodic or randomly structured wavefront markers (e.g.

View Article and Find Full Text PDF

Accurate 3D characterization of osteocyte lacunae is important when investigating the role of osteocytes under various physiological and pathological conditions but remains a challenge. With the continued development of laboratory X-ray micro-computed tomography, an increasing number of studies employ these techniques beyond traditional bone morphometry to quantify osteocyte lacunae. However, there is a lack of knowledge on the effect of measurement parameters on the image quality and resolution and in turn the osteocyte lacunar quantification.

View Article and Find Full Text PDF

Synchrotron X-ray micro-computed tomography enhances our knowledge of the skull anatomy of a Late Triassic ecteniniid cynodont with hypercanines.

Anat Rec (Hoboken)

January 2025

Instituto de Plasmas e Fusão Nuclear & Centro de Recursos Naturais e Ambiente (CERENA), Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal.

Hypercanines, or hypertrophied canines, are observed in a wide range of both extinct and extant synapsids. In non-mammaliaform cynodonts, the Permo-Triassic forerunners of mammals, long canines are not uncommon, appearing in several unrelated taxa within the clade. Among them is Trucidocynodon riograndensis, a carnivorous ecteniniid cynodont from the Late Triassic of Brazil, which exhibits a specialized dentition, including spear-shaped incisors, very long and narrow canines, and sectorial postcanines with distally oriented cusps, all of which have finely serrated margins.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!