The first X-ray Extended Range Technique (XERT)-like experiment at the Australian Synchrotron, Australia, is presented. In this experiment X-ray mass attenuation coefficients are measured across an energy range including the zinc K-absorption edge and X-ray absorption fine structure (XAFS). These high-accuracy measurements are recorded at 496 energies from 8.51 keV to 11.59 keV. The XERT protocol dictates that systematic errors due to dark current nonlinearities, correction for blank measurements, full-foil mapping to characterize the absolute value of attenuation, scattering, harmonics and roughness are measured over an extended range of experimental parameter space. This results in data for better analysis, culminating in measurement of mass attenuation coefficients across the zinc K-edge to 0.023-0.036% accuracy. Dark current corrections are energy- and structure-dependent and the magnitude of correction reached 57% for thicker samples but was still large and significant for thin samples. Blank measurements scaled thin foil attenuation coefficients by 60-500%; and up to 90% even for thicker foils. Full-foil mapping and characterization corrected discrepancies between foils of up to 20%, rendering the possibility of absolute measurements of attenuation. Fluorescence scattering was also a major correction. Harmonics, roughness and bandwidth were explored. The energy was calibrated using standard reference foils. These results represent the most extensive and accurate measurements of zinc which enable investigations of discrepancies between current theory and experiments. This work was almost fully automated from this first experiment at the Australian Synchrotron, greatly increasing the possibility for large-scale studies using XERT.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S1600577521005993DOI Listing

Publication Analysis

Top Keywords

attenuation coefficients
16
mass attenuation
12
extended range
12
x-ray absorption
8
x-ray extended
8
experiment australian
8
australian synchrotron
8
dark current
8
blank measurements
8
full-foil mapping
8

Similar Publications

Advances in nanomaterials for radiation protection in the aerospace industry: a systematic review.

Nanotechnology

December 2024

CCTS/DFQM, UFSCar - Campus Sorocaba, Rod. João Leme dos Santos km 110 - SP-264 Bairro do Itinga - Sorocaba CEP 18052-780, Sorocaba, 18052-780, BRAZIL.

Nanomaterials stand out for their exceptional properties and innovative potential, especially in applications that protect against space radiation. They offer an innovative approach to this challenge, demonstrating notable properties of radiation absorption and scattering, as well as flexibility and lightness for the development of protective clothing and equipment. This review details the use of polymeric materials, such as polyimides (PIs), which are efficient at attenuating ultraviolet (UV) radiation and atomic oxygen (AO).

View Article and Find Full Text PDF

Simulated low-dose dark-field radiography for detection of COVID-19 pneumonia.

PLoS One

December 2024

Chair of Biomedical Physics, Department of Physics & School of Natural Sciences, Technical University of Munich, Garching bei München, Germany.

Background: Dark-field radiography has been proven to be a promising tool for the assessment of various lung diseases.

Purpose: To evaluate the potential of dose reduction in dark-field chest radiography for the detection of the Coronavirus SARS-CoV-2 (COVID-19) pneumonia.

Materials And Methods: Patients aged at least 18 years with a medically indicated chest computed tomography scan (CT scan) were screened for participation in a prospective study between October 2018 and December 2020.

View Article and Find Full Text PDF

Introduction: This study aimed to investigate the clinical significance and potential mechanism of long non-coding RNA human histocompatibility leukocyte antigen complex P5 (HCP5) in neonatal sepsis (NS).

Material And Methods: The study enrolled 86 patients with NS and 80 neonates with respiratory tract infection or pneumonia. The Pearson correlation coefficient was used to evaluate the association of procalcitonin (PCT), C-reactive protein (CRP), and inflammatory factors with HCP5.

View Article and Find Full Text PDF

Barium fluoride borosilicate glass samples reinforced with varying amounts of GdO (BSBLG0-BSBLG4) have been manufactured using the conventional melt quenching procedure in order to provide additional research on the type of borosilicate glass. Structural, physical, and linear optical characteristics as well as γ-ray attenuation capacity of barium fluoride borosilicate doped with GdO was investigated. X-ray diffraction pattern proving the amorphous nature of the glass samples due to the absence of a distinctive crystalline characteristic peak.

View Article and Find Full Text PDF

Local magnitude (M) scales have been developed for Egypt based on 14,453 normalized Wood-Anderson amplitudes from 1670 earthquakes. These events were recorded by at least four seismic stations, with hypocentral depths of less than 40 km and earthquake magnitudes ranging from 0.1 to 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!