A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative Electron-Excited X-ray Microanalysis With Low-Energy L-shell X-ray Peaks Measured With Energy-Dispersive Spectrometry. | LitMetric

Quantification of electron-exited X-ray spectra following the standards-based “k-ratio” (unknown/standard intensity) protocol with corrections for “matrix effects” (electron energy loss and backscattering, X-ray absorption, and secondary X-ray fluorescence) is a well-established method with a record of rigorous testing and extensive experience. Two recent studies by Gopon et al. working in the Fe–Si system and Llovet et al. working in the Ni–Si system have renewed interest in studying the accuracy of measurements made using L-shell X-ray peaks. Both have reported unexpectedly large deviations in analytical accuracy when analyzing intermetallic compounds when using the low photon energy Fe or Ni L-shell X-ray peaks with pure element standards and wavelength-dispersive X-ray spectrometry. This study confirms those observations on the Ni-based intermetallic compounds using energy-dispersive X-ray spectrometry and extends the study of analysis with low photon energy L-shell peaks to a wide range of elements, Ti to Se. Within this range of elements, anomalies in analytical accuracy have been found for Fe, Co, and Ge in addition to Ni. For these elements, the use of compound standards instead of pure elements usually resulted in significantly improved analytical accuracy. However, compound standards do not always provide satisfactory accuracy as is demonstrated for L-shell peak analysis in the Fe–S system: FeS and FeS2 unexpectedly do not provide good accuracy when used as mutual standards.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10113020PMC
http://dx.doi.org/10.1017/S1431927621012617DOI Listing

Publication Analysis

Top Keywords

l-shell x-ray
12
x-ray peaks
12
analytical accuracy
12
x-ray
9
intermetallic compounds
8
low photon
8
photon energy
8
energy l-shell
8
x-ray spectrometry
8
range elements
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!