Organ-on-chip (OoC) systems are microfabricated cell culture devices designed to model functional units of human organs by harboring an generated organ surrogate. In the present study, we reviewed issues and opportunities related to the application of OoC in the safety and efficacy assessment of chemicals and pharmaceuticals, as well as the steps needed to achieve this goal. The relative complexity of OoC over simple assays provides advantages and disadvantages in the context of compound testing. The broader biological domain of OoC potentially enhances their predictive value, whereas their complexity present issues with throughput, standardization and transferability. Using OoCs for regulatory purposes requires detailed and standardized protocols, providing reproducible results in an interlaboratory setting. The extent to which interlaboratory standardization of OoC is feasible and necessary for regulatory application is a matter of debate. The focus of applying OoCs in safety assessment is currently directed to characterization (the biology represented in the test) and qualification (the performance of the test). To this aim, OoCs are evaluated on a limited scale, especially in the pharmaceutical industry, with restricted sets of reference substances. Given the low throughput of OoC, it is questionable whether formal validation, in which many reference substances are extensively tested in different laboratories, is feasible for OoCs. Rather, initiatives such as open technology platforms, and collaboration between OoC developers and risk assessors may prove an expedient strategy to build confidence in OoCs for application in safety and efficacy assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10408444.2021.1953439DOI Listing

Publication Analysis

Top Keywords

safety efficacy
8
efficacy assessment
8
reference substances
8
ooc
7
oocs
5
applicability organ-on-chip
4
organ-on-chip systems
4
systems toxicology
4
toxicology pharmacology
4
pharmacology organ-on-chip
4

Similar Publications

Dust emissions from open-pit mining pose a significant threat to environmental safety and human health. Currently, the range of dust suppressants used in coal mining is limited, often failing to account for their suitability across various stockpiles. This oversight results in poor infiltration after application, leading to insufficient crust formation and reduced durability.

View Article and Find Full Text PDF

Importance: Trials have not demonstrated superiority of alteplase or tenecteplase vs standard care in patients with mild stroke and have raised safety concerns. Prourokinase is an alternative fibrinolytic that may have a favorable safety profile, and the benefit-risk profile of prourokinase in mild stroke is unknown.

Objective: To investigate the efficacy and safety of prourokinase in mild ischemic stroke within 4.

View Article and Find Full Text PDF

Epilepsy is a common neurological disease that is treated with medications; however, patients with drug-resistant epilepsy, commonly intractable temporal lobe epilepsy, tend to have better control with surgical treatment. While the mainstay of surgical treatment is anterior temporal lobectomy, it carries risk of potential adverse effects hence minimally invasive techniques are now being used as an alternative to open surgery. This systematic review and meta-analysis compare the efficacy and safety of three of the most used techniques: laser interstitial thermal therapy (LITT), radiofrequency ablation (RFA) and stereotactic radiosurgery (SRS).

View Article and Find Full Text PDF

Chordoma is a rare malignant tumor with a higher incidence in males than in females. There is an increasing number of clinical studies related to tyrosine kinase inhibitors (TKIs), yet the efficacy and safety of different drugs vary. In this single-arm meta-analysis evaluating the efficacy and safety of TKIs for chordoma treatment, 12 studies involving 365 patients were analyzed.

View Article and Find Full Text PDF

Purpose: This phase II study is designed to evaluate the combination therapy involving suvemcitug and envafolimab with FOLFIRI in microsatellite-stable or mismatch repair-proficient (MSS/pMMR) colorectal cancer (CRC) in the second-line treatment setting.

Methods: This study is a non-randomized, open-label prospective study comprising multiple cohorts (NCT05148195). Here, we only report the data from the CRC cohort.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!