A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of a shoe lift on tensor fasciae latae length during standing with an artificial functional leg length discrepancy: An ultrasonic shear wave elastography study. | LitMetric

Background: Shortening of tensor fasciae latae is one factor that causes a functional leg length discrepancy. A shoe lift has been used to correct the compensatory posture resulting from the discrepancy. Despite the potential therapeutic benefit of a shoe lift, the mechanism by which it exerts its effect is unclear.

Objective: To investigate the effect of a shoe lift on tensor fasciae latae length during standing with an artificial functional leg length discrepancy using ultrasonic shear wave elastography.

Methods: Twenty-two healthy individuals performed static standing under three conditions: drop of the pelvis and flexion of the leg resulting from fixing in the hip abduction position using a hip orthosis (functional leg length discrepancy condition); drop of the pelvis by the orthosis, but no flexion of the leg due to a shoe lift (shoe lift condition); and normal bilateral standing condition. The shear elastic modulus of tensor fasciae latae was calculated using ultrasonic shear wave elastography.

Results: The shear elastic modulus was significantly lower in the functional leg length discrepancy condition than in the shoe lift and normal conditions (p= 0.038).

Conclusions: Using a shoe lift for the functional leg length discrepancy can result in a functional hip position that elongates tensor fasciae latae.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BMR-191755DOI Listing

Publication Analysis

Top Keywords

shoe lift
32
functional leg
24
leg length
24
length discrepancy
24
tensor fasciae
20
fasciae latae
20
ultrasonic shear
12
shear wave
12
shoe
8
lift tensor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!