Optical coherent domain reflectometry (OCDR) can achieve a high spatial resolution that is independent of the bandwidth of the receiver, but the measurement range is usually very limited. Here we propose an external modulation OCDR system, in which a pair of linear frequency-modulated pulses generated by one modulator are employed as the probe pulse and the reference, respectively. The spatial resolution is determined by the frequency modulation range of the pulse, and the measurement speed is boosted by orders because the proposed technology can simultaneously diagnose a section of fiber with each pair of pulses, while only a single point can be accessed at a time in typical OCDR. In the demonstrational experiment, a measurement range of up to 50 km is achieved with a spatial resolution of 1.4 m and a measuring time of less than 30 s.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8401056PMC
http://dx.doi.org/10.3390/s21165510DOI Listing

Publication Analysis

Top Keywords

measurement range
12
spatial resolution
12
external modulation
8
optical coherent
8
coherent domain
8
domain reflectometry
8
modulation optical
4
reflectometry long
4
measurement
4
long measurement
4

Similar Publications

Urban environments are exposed to a substantial range of anthropic pressures, including chemical exposure. While trace metals and legacy pollutants have been well documented, the extent of wildlife exposure to emerging contaminants has received little attention, in terrestrial mammals. Concentrations of trace elements (Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Pb and Zn) and 48 organic pollutants (Polychlorinated Biphenyls: PCBs, Organochlorine Pesticides: OCPs, Polycyclic Aromatic Hydrocarbons: PAHs, phthalates and pyrethroid pesticides) were measured in tissues of European hedgehogs (Erinaceus europaeus) in southern Sweden.

View Article and Find Full Text PDF

Validation of lactate and glucose in cerebrospinal fluid (CSF) on a Radiometer blood gas analyzer ABL90 Flex plus.

Clin Biochem

January 2025

Pathology and Laboratory Medicine Program, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada; Memorial University of Newfoundland, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada. Electronic address:

Purpose: Rapid determination of cerebrospinal fluid. (CSF) glucose and lactate is required by emergency rooms and intensive care units. Long turnaround time (TAT) on test results negatively impacts timely diagnosis and treatment of neurological infections like meningitis.

View Article and Find Full Text PDF

Comprehensive determination of elements ranging from uranium to americium by hybrid measurement of fluorescent and spontaneously emitted characteristic X-rays.

Talanta

January 2025

National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Chiba, Chiba, 263-8555, Japan; Department of Physics, Faculty of Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba, 274-8510, Japan.

Natural uranium isotopes have extremely long half-lives; therefore, analytical methods based on the number of atoms, such as X-ray fluorescence (XRF) analysis, are suitable for uranium detection. However, XRF measurements cannot be used to detect the major isotopes of americium when present in amounts barely detectable using radiation measurements, owing to their relatively short half-lives. Because of α-decay-induced internal conversion, where orbital electrons are emitted instead of γ-rays, these nuclides emit characteristic X-rays.

View Article and Find Full Text PDF

Introduction: Behaviour change interventions have the potential to improve sanitation and hygiene practices in urban settings. However, evidence on which behaviour change interventions have successfully improved sanitation and hygiene practices in urban settings is unclear.

Methods: We performed electronic searches across five databases and one grey literature database to identify relevant studies published between January 1, 1990 and November 20, 2023 in English.

View Article and Find Full Text PDF

Soft capacitive sensors are widely utilized in wearable devices, flexible electronics, and soft robotics due to their high sensitivity. However, they may suffer delamination and/or debonding due to their low interfacial toughness. In addition, they usually exhibit a small measurement range resulting from their limited stiffness variation range.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!