A MedRadio RF receiver integrated circuit for implanted and wearable biomedical devices must be resilient to the out-of-band (OOB) orthogonal frequency division modulation (OFDM) blocker. As the OFDM is widely adopted for various broadcasting and communication systems in the ultra-high frequency (UHF) band, the selectivity performance of the MedRadio RF receiver can severely deteriorate by the second-order intermodulation (IM2) distortion induced by the OOB OFDM blocker. An analytical investigation shows how the OFDM-induced IM2 distortion power can be translated to an equivalent two-tone-induced IM2 distortion power. It makes the OFDM-induced IM2 analysis and characterization process for a MedRadio RF receiver much simpler and more straightforward. A MedRadio RF receiver integrated circuit with a significantly improved resilience to the OOB IM2 distortion is designed in 65 nm complementary metal-oxide-semiconductor (CMOS). The designed RF receiver is based on low-IF architecture, comprising a low-noise amplifier, single-to-differential transconductance stage, quadrature passive mixer, trans-impedance amplifier (TIA), image-rejecting complex bandpass filter, and fractional phase-locked loop synthesizer. We describe design techniques for the IM2 calibration through the gate bias tuning at the mixer, and the dc offset calibration that overcomes the conflict with the preceding IM2 calibration through the body bias tuning at the TIA. Measured results show that the OOB carrier-to-interference ratio (CIR) performance is significantly improved by 4-11 dB through the proposed IM2 calibration. The measured maximum tolerable CIR is found to be between -40.2 and -71.2 dBc for the two-tone blocker condition and between -70 and -77 dBc for the single-tone blocker condition. The analytical and experimental results of this work will be essential to improve the selectivity performance of a MedRadio RF receiver against the OOB OFDM-blocker-induced IM2 distortion and, thus, improve the robustness of the biomedical devices in harsh wireless environments in the MedRadio and UHF bands.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400011 | PMC |
http://dx.doi.org/10.3390/s21165303 | DOI Listing |
Sensors (Basel)
August 2021
Department of Electronics Convergence Engineering, Kwangwoon University, Seoul 01897, Korea.
A MedRadio RF receiver integrated circuit for implanted and wearable biomedical devices must be resilient to the out-of-band (OOB) orthogonal frequency division modulation (OFDM) blocker. As the OFDM is widely adopted for various broadcasting and communication systems in the ultra-high frequency (UHF) band, the selectivity performance of the MedRadio RF receiver can severely deteriorate by the second-order intermodulation (IM2) distortion induced by the OOB OFDM blocker. An analytical investigation shows how the OFDM-induced IM2 distortion power can be translated to an equivalent two-tone-induced IM2 distortion power.
View Article and Find Full Text PDFIEEE Trans Biomed Circuits Syst
April 2019
Background And Objective: In-body biotelemetry devices enable wireless monitoring of a wide range of physiological parameters. These devices rely on antennas to interface with external receivers, yet existing systems suffer from impedance detuning caused by the substantial differences in electromagnetic properties among various tissues. In this paper, we propose an immune-to-detuning in-body biotelemetry platform featuring a novel tissue-independent antenna design.
View Article and Find Full Text PDFThis paper presents a low-power integrated wireless telemetry system (Bio-WiTel) for healthcare applications in 401-406 MHz frequency band of medical device radiocommunication (MedRadio) spectrum. In this paper, necessary design considerations for telemetry system for short-range (upto 3 m) communication of biosignals are presented. These considerations help greatly in making important design decisions, which eventually lead to a simple, low power, robust, and reliable wireless system implementation.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2015
A 4-Mbps 400-MHz On-Off Keying (OOK) receiver implemented in 0.18-um CMOS technology for implantable epilepsy sense-and-stimulation devices is presented. The proposed receiver is composed of a new current-mode full-wave envelope detector and differential cascaded gain amplifiers which is operated at MedRadio band.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!