Objective: To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia).
Materials And Methods: A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: "in situ aging" (non-aged and aged (A)) and "finishing/polishing" (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (μm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey's test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal-Wallis tests.
Results: For flexural resistance, the "finishing/polishing" factor was statistically significant (P = 0.0001); however, the "in situ aging" factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m.
Conclusions: The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion.
Clinical Relevance: Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9902030 | PMC |
http://dx.doi.org/10.1007/s00784-021-04068-3 | DOI Listing |
Water Sci Technol
November 2024
Department of Civil and Environmental Engineering, School of Urban Environmental Sciences, Tokyo Metropolitan University, 1-1, Minami-osawa, Hachioji-city, Tokyo 192-0397, Japan.
Introducing microplastics (MPs) into the marine environment is a global problem. Tire-derived microplastics (TMPs) are estimated to account for 60% of all secondary MPs dispersed in aquatic environments. To effectively detect TMPs in environmental samples using micro-Fourier transform infrared (μFTIR) spectroscopy, a high-quality reference library is essential.
View Article and Find Full Text PDFJ Funct Biomater
September 2024
Department of Prosthodontics, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia.
Esthetically pleasing temporary prostheses are often necessary for extended periods in a variety of clinical scenarios. Adjustments to the occlusion or margins are commonly needed before cementing the temporary prosthesis. Therefore, it is clinically necessary to repolish the rough surface to avoid biological and esthetic issues associated with rough surfaces.
View Article and Find Full Text PDFJ Clin Exp Dent
June 2024
São Leopoldo Mandic Institute and Dental Research Center, Campinas, SP, Brazil.
Background: To evaluate the effect of different finishing and polishing systems on the surface roughness and color changes of bis-acryl (Protemp 4 - 3M ESPE- St. Paul, USA; Structur 3 - Voco, Cuxhaven, Germany) and chemically activated acrylic materials (Duralay - Reliance, SP, Brazil).
Material And Methods: Specimens (10 x 2 mm) thick were prepared for each material.
J Clin Exp Dent
June 2024
DDS, MS, PhD. Professor. Division of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
Background: Considering the variability of finishing protocols for composite resins, the literature does not offer a consensus about the influence of these approaches to obtain a final polishing and whether the physical properties of these composite resins change at different analysis times. Therefore, the study analyzed the microhardness, roughness, color stability, and gloss of a nanocomposite resin with different finishing, aging with coffee, and repolishing protocols.
Material And Methods: Nanocomposite resin samples were divided into three finishing protocol groups: Diamond burs (F and FF), multi-fluted tungsten carbide burs (18 and 30 flutes), and coarse and medium abrasive discs (Soflex-3M).
Materials (Basel)
July 2024
Deptartment of Materials Engineering, Lublin University of Technology, 20-618 Lublin, Poland.
Dental composites are gaining great popularity in restorative dentistry because of their aesthetic appeal and capacity to replicate the natural color of teeth. Nevertheless, their lifespan and durability rely on various factors, such as the polishing technique and the environmental conditions they are exposed to. The study aimed to assess the influence of the method of final polishing of dental composite on the surface roughness and microhardness of materials also considering the environment of different pHs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!