Background: Treating orbital injuries is interesting and difficult in the facial trauma. The balance in facial proportions and also the facial esthetics are required to achieve an anatomical harmony.

Objective: To compare the functional results of individual reconstruction of orbital floor using either titanium mesh or Medpor in terms of various factors.

Materials And Methods: There were two study groups including eight subjects with orbital floor fracture, namely A (Medpor) and B (titanium mesh). Various parameters were analyzed postoperatively at intervals of 1 week, 3 week, 6 week, and 3 months after the surgery.

Statistical Analysis: Comparison of the different time points with respect to pain scores in the two study groups by Wilcoxon matched pairs test was done. value was significant in the study Group A with = 0.0431* and was insignificant in the study Group B with = 0.1088.

Results: All three cases of titanium mesh in orbital floor reconstruction had signs of infection, tenderness, and radiographic proof after 1 week in two subjects and 3 weeks in one patient. Pain was seen in all eight patients 1 week postoperatively.

Conclusion: Although orbital reconstruction is a technique sensitive procedure both Medpore and Titanium mesh functions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8375837PMC
http://dx.doi.org/10.4103/jpbs.JPBS_553_20DOI Listing

Publication Analysis

Top Keywords

titanium mesh
20
orbital floor
16
study groups
8
week week
8
study group
8
orbital
6
titanium
5
study
5
week
5
mesh versus
4

Similar Publications

Metallic biomaterials are extensively used in orthopedics and dentistry, either as implants or coatings. In both cases, metal ions come into contact with surrounding tissues causing a particular cell response. Here, we present a biofabricated tissue model, consisting of a hydrogel reinforced with a melt electrowritten mesh, to study the effects of bound and released metal ions on surrounding cells embedded in a hydrogel matrix.

View Article and Find Full Text PDF

Background: Posterior vault distraction osteogenesis (PVDO) is an effective treatment for multisuture and syndromic craniosynostosis. It remains unclear how well the calvarium ossifies after PVDO, especially in older patients when they have plateaued in their cranial growth phase. The purpose of this study is to report outcomes associated with PVDO across a wide range of ages at our institution.

View Article and Find Full Text PDF

Evaluation of sticky bone in guided bone regeneration in the aesthetic area of the anterior teeth: a retrospective study.

Int J Oral Maxillofac Surg

January 2025

Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:

The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.

View Article and Find Full Text PDF

Intracranial Hypotension Mechanism and Implant Retention Procedure for Patients With Titanium Mesh Exposure.

Oper Neurosurg (Hagerstown)

January 2025

Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China.

Background And Objectives: The study aimed to investigate the potential pathogenesis and present an implant retention procedure for patients with titanium mesh exposure after cranioplasty.

Methods: The clinical data were obtained from 26 consecutive cases with titanium mesh exposure who underwent surgical treatment between 2018 and 2023. These patients' medical records, scalp photographs, operative notes, and outcomes were retrospectively analyzed.

View Article and Find Full Text PDF
Article Synopsis
  • Cage subsidence can negatively affect lumbar fusion procedures, with material selection (PEEK vs. 3D-Ti) influencing this issue; the study aims to compare their subsidence rates.
  • The systematic search reviewed 265 patients from three high-quality studies, focusing on cage subsidence and classified subsidence rates using a specific method.
  • Results indicated that 3D-Ti cages have a significantly lower rate of subsidence compared to PEEK cages, with less severe subsidence and better overall performance.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!