Mechanical stress is an important factor affecting bone tissue homeostasis. We focused on the interactions among mechanical stress, glucose uptake via glucose transporter 1 (Glut1), and the cellular energy sensor sirtuin 1 (SIRT1) in osteoblast energy metabolism, since it has been recognized that SIRT1, an NAD+-dependent deacetylase, may function as a master regulator of the mechanical stress response as well as of cellular energy metabolism (glucose metabolism). In addition, it has already been demonstrated that SIRT1 regulates the activity of the osteogenic transcription factor runt-related transcription factor 2 (Runx2). The effects of mechanical loading on cellular activities and the expressions of Glut1, SIRT1, and Runx2 were evaluated in osteoblasts and chondrocytes in a 3D cell-collagen sponge construct. Compressive mechanical loading increased osteoblast activity. Mechanical loading also significantly increased the expression of Glut1, significantly decreased the expression of SIRT1, and significantly increased the expression of Runx2 in osteoblasts in comparison with non-loaded osteoblasts. Incubation with a Glut1 inhibitor blocked mechanical stress-induced changes in SIRT1 and Runx2 in osteoblasts. In contrast with osteoblasts, the expressions of Glut1, SIRT1, and Runx2 in chondrocytes were not affected by loading. Our present study indicated that mechanical stress induced the upregulation of Glut1 following the downregulation of SIRT1 and the upregulation of Runx2 in osteoblasts but not in chondrocytes. Since SIRT1 is known to negatively regulate Runx2 activity, a mechanical stress-induced downregulation of SIRT1 may lead to the upregulation of Runx2, resulting in osteoblast differentiation. Incubation with a Glut1 inhibitor the blocked mechanical stress-induced downregulation of SIRT1 following the upregulation of Runx2, suggesting that Glut1 is necessary to mediate the responses of SIRT1 and Runx2 to mechanical loading in osteoblasts.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8396442 | PMC |
http://dx.doi.org/10.3390/ijms22169070 | DOI Listing |
Adv Sci (Weinh)
January 2025
Institute for Electrochemical Energy Storage (CE-IEES), Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109, Berlin, Germany.
Sn-based electrodes are promising candidates for next-generation lithium-ion batteries. However, it suffers from deleterious micro-structural deformation as it undergoes drastic volume changes upon lithium insertion and extraction. Progress in designing these materials is limited to complex structures.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Pain Medicine, Aichi Medical University, Nagakute, Aichi, Japan.
Background: Lowering barometric pressure (LP) can exacerbate neuropathic pain. However, animal studies in this field are limited to a few conditions. Furthermore, although sympathetic involvement has been reported as a possible mechanism, whether the sympathetic nervous system is involved in the hypothalamic-pituitary-adrenal (HPA) axis remains unknown.
View Article and Find Full Text PDFClin Implant Dent Relat Res
February 2025
Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
Introduction: Implantology has become a primary solution for tooth loss due to excellent osseointegration and high long-term success rates. However, complications such as abutment screw loosening, especially in implant-supported single crowns, compromise prosthesis longevity. Anaerobic adhesives (AAs) have shown promise in mechanical fields for preventing screw loosening, but their effectiveness in dental implants, particularly zirconia, remains uncertain.
View Article and Find Full Text PDFJ Clin Exp Dent
December 2024
Faculty of Dentistry of Pernambuco, University of Pernambuco, 50100130, Recife, Pernambuco, Brasil.
Background: To analyze the biomechanical and functional characteristics of different maxillary fixation techniques after Le Fort I osteotomy and occlusal plane rotation, using the finite element method to simulate the mechanical behavior of three different osteosynthesis approaches.
Material And Methods: This is a virtual experimental study carried out using finite element analysis to compare three different osteosynthesis techniques after Le Fort I osteotomy and rotation of the maxillary occlusal plane. Three configurations were tested: four-point fixation with "L" plates (C1), two-point fixation with "L" plates (C2), and two-point fixation with pre-modeled Lindorf plates (C3).
Eur Heart J Case Rep
January 2025
Department of Radiological and Hematological Sciences, Section of Radiology, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8 - 00168 Rome, Italy.
Background: Cardiac strangulation (CS) from epicardial pacing leads (EPLs) is a rare and potentially lethal mechanical complication associated with epicardial pacemaker (PM) implantation.
Case Summary: We report a case of a 44-year-old-female patient presenting with chest and left shoulder pain in the absence of reported trauma with history of congenital atrioventricular block treated with epicardial PM implantation during the childhood and subsequent transvenous reimplantation over the years. Troponin I resulted within normal values and ECG, transthoracic echocardiography and chest X-ray documented no acute cardiopulmonary findings.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!