The accuracy of the implant's post-operative position and orientation in reverse shoulder arthroplasty is known to play a significant role in both clinical and functional outcomes. Whilst technologies such as navigation and robotics have demonstrated superior radiological outcomes in many fields of surgery, the impact of augmented reality (AR) assistance in the operating room is still unknown. Malposition of the glenoid component in shoulder arthroplasty is known to result in implant failure and early revision surgery. The use of AR has many promising advantages, including allowing the detailed study of patient-specific anatomy without the need for invasive procedures such as arthroscopy to interrogate the joint's articular surface. In addition, this technology has the potential to assist surgeons intraoperatively in aiding the guidance of surgical tools. It offers the prospect of increased component placement accuracy, reduced surgical procedure time, and improved radiological and functional outcomes, without recourse to the use of large navigation or robotic instruments, with their associated high overhead costs. This feasibility study describes the surgical workflow from a standardised CT protocol, via 3D reconstruction, 3D planning, and use of a commercial AR headset, to AR-assisted k-wire placement. Post-operative outcome was measured using a high-resolution laser scanner on the patient-specific 3D printed bone. In this proof-of-concept study, the discrepancy between the planned and the achieved glenoid entry point and guide-wire orientation was approximately 3 mm with a mean angulation error of 5°.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8400865 | PMC |
http://dx.doi.org/10.3390/jpm11080777 | DOI Listing |
Alkaptonuria (AKU) is an extremely rare autosomal recessive metabolic disorder caused by deficiency of homogentisic acid oxidase and resulting in accumulation of homogentisic acid in collagenous structures. It is characterized by a triad of homogentisic aciduria, bluish-black discoloration of connective tissues (ochronosis) and arthropathy of large weight bearing joints. We report on a middle-aged female patient with bilateral severe ochronotic arthritis of both hips and shoulder joints requiring total joint replacements as staged procedures which were done without complications offering a complete pain relief and a satisfactory clinical and functional outcome.
View Article and Find Full Text PDFJ Clin Orthop Trauma
February 2025
Trauma and Orthopaedics East and North Hertfordshire NHS Trust Lister Hospital, Stevenage, UK.
Background: There has been an increasing interest in elbow hemiarthroplasty to circumvent the problems with total elbow arthroplasty for comminuted distal humerus fractures in the elderly. The primary aim of the study is to assess the mid-term clinical and radiological outcomes of patients undergoing TEA and hemiarthroplasty for distal humerus fractures.
Methods: Retrospective analysis of data for patients undergoing hemiarthroplasty for distal humerus fractures (OTA- C3 Comminuted total articular fractures) was done.
J Clin Orthop Trauma
March 2025
Department of Orthopaedics, Woodend Hospital, Aberdeen, AB15 6XS, UK.
Reverse shoulder arthroplasty (RSA) has witnessed a significant advancement with the introduction of lateralisation techniques, aiming to enhance shoulder function and implant durability. Traditional medialised designs, following Grammont's principles, have encountered challenges such as scapular notching, reduced rotational strength, and instability. In contrast, lateralisation methods, which reposition the joint center of rotation laterally on the glenoid, humerus, or both, seek to improve deltoid leverage, optimize the rotator cuff muscles' length-tension relationship, and enhance joint stability.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Department of Orthopaedic Surgery, North Shore Hospital, Takapuna, Auckland, New Zealand; Department of Surgery, University of Auckland, Grafton, Auckland, New Zealand.
Hypothesis And Background: The incidence of prosthetic joint infection (PJI) remains high following elbow arthroplasty procedures. The purpose of this study was to investigate whether Surgical Helmet Systems (SHS) reduce rates of PJI after elbow arthroplasty in a population-based registry study over a consecutive 23-year period. We hypothesized SHS would reduce the incidence of PJI compared with conventional surgical gowns following elbow arthroplasty surgery.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Department of Rehabilitation Sciences, Faculty of Medicine and Health Sciences, Ghent University, Campus UZ Gent, Ghent, Belgium.
Background: Reversed shoulder arthroplasty (rTSA) is often used to restore functionality in patients with joint arthropathy and dysfunctional rotator cuff. As rTSA changes the biomechanical properties of the shoulder, an altered movement pattern of arm and scapula is to be expected. Previous studies focused on changes of the scapulohumeral rhythm during functional elevation tasks.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!