A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Colorimetry-Based Detection of Nitric Oxide from Exhaled Breath for Quantification of Oxidative Stress in Human Body. | LitMetric

Monitoring exhaled breath is a safe, noninvasive method for determining the health status of the human body. Most of the components in our exhaled breath can act as health biomarkers, and they help in providing information about various diseases. Nitric oxide (NO) is one such important biomarker in exhaled breath that indicates oxidative stress in our body. This work presents a simple and noninvasive quantitative analysis approach for detecting NO from exhaled breath. The sensing is based on the colorimetric assisted detection of NO by m-Cresol Purple, Bromophenol Blue, and Alizaringelb dye. The sensing performance of the dye was analyzed by ultraviolet-visible (UV-Vis) spectroscopy. The study covers various sampling conditions like the pH effect, temperature effect, concentration effect, and selective nature of the dye. The m-Cresol Purple dye exhibited a high sensitivity towards NO with a detection limit of ~0.082 ppm in the linear range of 0.002-0.5 ppm. Moreover, the dye apprehended a high degree of selectivity towards other biocompounds present in the breath, and no possible interfering cross-reaction from these species was observed. The dye offered a high sensitivity, selectivity, fast response, and stability, which benchmark its potential for NO sensing. Further, m-Cresol Purple dye is suitable for NO sensing from the exhaled breath and can assist in quantifying oxidative stress levels in the body for the possible detection of COVID-19.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8391997PMC
http://dx.doi.org/10.3390/healthcare9081055DOI Listing

Publication Analysis

Top Keywords

exhaled breath
24
oxidative stress
12
m-cresol purple
12
nitric oxide
8
human body
8
purple dye
8
high sensitivity
8
breath
7
dye
7
exhaled
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!