A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of a Global Multiparameter Scoring System for the Prenatal Prediction of Coarctation of the Aorta. | LitMetric

Application of a Global Multiparameter Scoring System for the Prenatal Prediction of Coarctation of the Aorta.

J Clin Med

Fetal Medicine Unit, Department of Obstetrics and Gynecology, University Hospital 12 de Octubre, 12 de Octubre Research Institute (imas12), Complutense University of Madrid, 28041 Madrid, Spain.

Published: August 2021

To assess prospectively the capability of our previously reported global multiparameter scoring system to predict coarctation of the aorta (CoAo) in fetuses with cardiac asymmetry, we applied and analyzed the performance of our scoring system in predicting postnatal CoAo in fetuses undergoing prenatal echocardiographic assessment because of cardiac asymmetry between 2011 and 2021, and we determined the cut-off points of the score with the best balance between specificity and sensitivity, and of maximum sensitivity and specificity. CoAo was confirmed in 39/179 newborns (21.8%). We found a significantly higher probability of CoAo in fetuses with CoAo than in cases without CoAo (84.2 ± 18.2% vs. 26.0 ± 28.6%, < 0.001). The AUC of the ROC of the score was 0.93 (95% CI 0.89-0.97). The cut-off value with the best balance between specificity and sensitivity was a predicted risk of ≥53% (sensitivity 92.3% and specificity 80.0%). The cut-off point of maximum sensitivity was ≥35% (sensitivity 100% and specificity 72.9%), and that of maximum specificity was ≥96% (sensitivity 43.6% and specificity 96.4%). In none of the fetuses with a probability of CoAo < 35% was this condition confirmed after birth. This occurred in 102 fetuses in the whole study population (57%) and in 84 of the 111 in whom CoAo was suspected beyond 28 weeks (75.7%). This multiparameter score allows an adequate discrimination between fetuses without CoAo and those with CoAo, reducing the false positive diagnoses in cardiac asymmetry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8397204PMC
http://dx.doi.org/10.3390/jcm10163690DOI Listing

Publication Analysis

Top Keywords

scoring system
12
coao fetuses
12
cardiac asymmetry
12
coao
10
global multiparameter
8
multiparameter scoring
8
coarctation aorta
8
best balance
8
balance specificity
8
specificity sensitivity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!