Introduction: In acute COVID-19, D-Dimer levels can be elevated and those patients are at risk for thromboembolic events. This study aims to investigate differences in preoperative D-Dimer levels in SARS-CoV-2 IgG positive and negative patients undergoing primary total knee and total hip replacement (TJA) or spine surgery.
Methods: D-Dimer levels of 48 SARS-CoV-2 IgG positive and 718 SARS-CoV-2 IgG negative spine surgery patients were compared to those of 249 SARS-CoV-2 IgG positive and 2102 SARS-CoV-2 IgG negative TJA patients. Patients were assigned into groups based on D-Dimer levels as follows: <200 ng/mL, 200-400 ng/mL, and >400 ng/mL D-Dimer Units (DDU).
Results: D-Dimer levels did neither differ significantly between SARS-CoV-2 IgG positive spine surgery patients and TJA patients ( = 0.1), nor between SARS-CoV-2 IgG negative spine surgery and TJA patients ( = 0.7). In addition, there was no difference between SARS-CoV-2 IgG positive and negative spine surgery patients and SARS-CoV-2 IgG positive and negative TJA patients ( = 0.3).
Conclusions: There is no difference in D-Dimer levels between SARS-CoV-2 IgG positive and negative patients and there does not seem to be any difference for different orthopedic specialty patients. Routine testing of D-Dimer levels is not recommended for patients undergoing elective orthopedic surgery.