A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiomics Nomogram Based on Radiomics Score from Multiregional Diffusion-Weighted MRI and Clinical Factors for Evaluating HER-2 2+ Status of Breast Cancer. | LitMetric

This study aimed to establish and validate a radiomics nomogram using the radiomics score (rad-score) based on multiregional diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) features combined with clinical factors for evaluating HER-2 2+ status of breast cancer. A total of 223 patients were retrospectively included. Radiomic features were extracted from multiregional DWI and ADC images. Based on the intratumoral, peritumoral, and combined regions, three rad-scores were calculated using the logistic regression model. Independent parameters were selected among clinical factors and combined rad-score (com-rad-score) using multivariate logistic analysis and used to construct a radiomics nomogram. The performance of the nomogram was evaluated using calibration, discrimination, and clinical usefulness. The areas under the receiver operator characteristic curve (AUCs) of intratumoral and peritumoral rad-scores were 0.824/0.763 and 0.794/0.731 in the training and validation cohorts, respectively. Com-rad-score achieved the highest AUC (0.860/0.790) among three rad-scores. ER status and com-rad-score were selected to establish the nomogram, which yielded good discrimination (AUC: 0.883/0.848) and calibration. Decision curve analysis demonstrated the clinical value of the nomogram in the validation cohort. In conclusion, radiomics nomogram, including clinical factors and com-rad-score, showed favorable performance for evaluating HER-2 2+ status in breast cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8395031PMC
http://dx.doi.org/10.3390/diagnostics11081491DOI Listing

Publication Analysis

Top Keywords

radiomics nomogram
16
clinical factors
16
evaluating her-2
12
her-2 status
12
status breast
12
breast cancer
12
radiomics score
8
multiregional diffusion-weighted
8
factors evaluating
8
intratumoral peritumoral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!