The impaired blood flow to the brain causes a decrease in the supply of oxygen that can result in cerebral ischemia; if the blood flow is not restored quickly, neuronal injury or death will occur. Under hypoxic conditions, the production of nitric oxide (NO), via the classical L-arginine-NO synthase pathway, is reduced, which can compromise NO-dependent vasodilation. However, the alternative nitrite (NO) reduction to NO, under neuronal hypoxia and ischemia conditions, has been viewed as an in vivo storage pool of NO, complementing its enzymatic synthesis. Brain research is thus demanding suitable tools to probe nitrite's temporal and spatial dynamics in vivo. In this work, we propose a new method for the real-time measurement of nitrite concentration in the brain extracellular space, using fast-scan cyclic voltammetry (FSCV) and carbon microfiber electrodes as sensing probes. In this way, nitrite was detected anodically and in vitro, in the 5-500 µM range, in the presence of increasing physiological concentrations of ascorbate (100-500 µM). These sensors were then tested for real-time and in vivo recordings in the anesthetized rat hippocampus; using fast electrochemical techniques, local and reproducible transients of nitrite oxidation signals were observed, upon pressure ejection of an exogenous nitrite solution into the brain tissue. Nitrite microsensors are thus a valuable tool for investigating the role of this inorganic anion in brain redox signaling.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8394717PMC
http://dx.doi.org/10.3390/bios11080277DOI Listing

Publication Analysis

Top Keywords

blood flow
8
nitrite
7
brain
6
microelectrode sensor
4
sensor real-time
4
real-time measurements
4
measurements nitrite
4
nitrite living
4
living brain
4
brain presence
4

Similar Publications

Cytoskeletal remodeling and mitochondrial bioenergetics play important roles in thrombocytopoiesis and platelet function. Recently, α-actinin-1 mutations have been reported in patients with congenital macrothrombocytopenia. However, the role and underlying mechanism of α-actinin-1 in thrombocytopoiesis and platelet function remain elusive.

View Article and Find Full Text PDF

Introduction: Hemorrhage is the leading cause of preventable deaths in trauma patients, resulting in 1.5 million deaths annually worldwide. Traditional trauma assessment follows the ABC (airway, breathing, circulation) sequence; evidence suggests the CAB (circulation, airway, breathing) approach to maintain perfusion and prevent hypotension.

View Article and Find Full Text PDF

Background: The challenges associated with traditional drug screening, such as high costs and long screening times, have led to an increase in the use of single-cell isolation technologies. Small sample volumes are required for high-throughput, cell-based assays to reduce assay costs and enable rapid sample processing. Using microfluidic chips, single-cell analysis can be conducted more effectively, requiring fewer reagents and maintaining biocompatibility.

View Article and Find Full Text PDF

Little is known about the effects of sodium-glucose co-transporter 2 inhibitors (SGLT2i) on atherosclerosis. We aimed to determine if a 90-day intake of Dapagliflozin could improve atherosclerosis biomarkers (namely endothelial function assessed by flow-mediated dilatation [FMD] and carotid intima-media thickness [CIMT]) in diabetic and non-diabetic acute coronary syndrome (ACS) patients when initiated in the early in-hospital phase. ATH-SGLT2i was a prospective, single-center, observational trial that included 113 SGLT2i naive patients who were admitted for ACS and who were prescribed Dapagliflozin at a fixed dose of 10 mg during their hospital stay for either type 2 diabetes or for heart failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!