A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Inverse Kinematics of Concentric Tube Robots in the Presence of Environmental Constraints. | LitMetric

Inverse kinematics (IK) of concentric tube continuum robots (CTRs) is associated with two main problems. First, the robot model (e.g., the relationship between the configuration space parameters and the robot end-effector) is not linear. Second, multiple solutions for the IK are available. This paper presents a general approach to solve the IK of CTRs in the presence of constrained environments. It is assumed that the distal tube of the CTR is inserted into a cavity while its proximal end is placed inside a tube resembling the vessel enabling the entry to the organ cavity. The robot-tissue interaction at the beginning of the organ-cavity imposed displacement and force constraints to the IK problem to secure a safe interaction between the robot and tissue. The IK in CTRs has been carried out by treating the problem as an optimization problem. To find the optimized IK of the CTR, the cost function is defined to be the minimization of input force into the body cavity and the occupied area by the robot shaft body. The optimization results show that CTRs can keep the safe force range in interaction with tissue for the specified trajectories of the distal tube. Various simulation scenarios are conducted to validate the approach. Using the IK obtained from the presented approach, the tracking accuracy is achieved as 0.01 mm which is acceptable for the application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8382537PMC
http://dx.doi.org/10.1155/2021/4107732DOI Listing

Publication Analysis

Top Keywords

inverse kinematics
8
kinematics concentric
8
concentric tube
8
distal tube
8
tube
5
tube robots
4
robots presence
4
presence environmental
4
environmental constraints
4
constraints inverse
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!