Since the discovery of polydopamine (PDA), there has been a lot of progress on using this substance to functionalize many different surfaces. However, little attention has been given to prepare functionalized surfaces for the preparation of flexible electrochemical paper-based devices. After fabricating the electrodes on paper substrates, we formed PDA on the surface of the working electrode using a chemical polymerization route. PDA nanofilms on carbon were characterized by contact angle (CA) experiments, X-ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy (topography and electrical measurements) and electrochemical techniques. We observed that PDA introduces chemical functionalities (RNH and RC═O) that decrease the CA of the electrode. Moreover, PDA nanofilms did not block the heterogeneous electron transfer. In fact, we observed one of the highest standard heterogeneous rate constants (k ) for electrochemical paper-based electrodes (2.5 ± 0.1) × 10 cm s , which is an essential parameter to obtain larger currents. In addition, our results suggest that carbonyl functionalities are ascribed for the redox activity of the nanofilms. As a proof-of-concept, the electrooxidation of nicotinamide adenine dinucleotide showed remarkable features, such as, lower oxidation potential, electrocatalytic peak currents more than 30 times higher when compared to unmodified paper-based electrodes and electrocatalytic rate constant (k ) of (8.2 ± 0.6) × 10 L mol s .
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bip.23472 | DOI Listing |
Anal Chem
January 2025
Laboratory of Analytical Chemistry, Department of Chemistry, University of Athens, Athens 157 71, Greece.
This work describes fully integrated multifolding electrochemical paper-based devices (ePADs) for enhanced multiplexed voltammetric determination of heavy metals (Zn(II), Cd(II), and Pb(II)) using tunable passive preconcentration. The paper devices integrate five circular sample preconcentration layers and a 3-electrode electrochemical cell. The hydrophobic barriers of the devices are drawn by pen-plotting with hydrophobic ink, while the electrodes are deposited by screen-printing.
View Article and Find Full Text PDFTalanta
December 2024
Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing, China. Electronic address:
Accurate analysis of urinary creatinine levels is of great clinical significance. Non-enzymatic creatinine sensing systems (NECSs) have gained growing development because of higher stability and lower cost compared to enzymatic sensing systems. At present, there is a demand for simple approaches to develop NECSs with high sensitivity.
View Article and Find Full Text PDFBiosensors (Basel)
December 2024
Department of Electrical-Electronics Engineering, Abdullah Gul University, Kayseri 38039, Türkiye.
detection suffers from slow analysis time and high costs, along with the need for specificity. While state-of-the-art electrochemical biosensors are cost-efficient and easy to implement, their sensitivity and analysis time still require improvement. In this work, we present a paper-based electrochemical biosensor utilizing magnetic core-shell FeO@CdSe/ZnS quantum dots (MQDs) to achieve fast detection, low cost, and high sensitivity.
View Article and Find Full Text PDFTalanta
December 2024
Department of Sensor and Biomedical Technology, School of Electronics Engineering (SENSE), Vellore Institute of Technology, Vellore, 632014, India. Electronic address:
Monitoring real-time health conditions is a rinsing demand in a pandemic prone era. Wearable Point-of-Care (POC) devices with paper and fabric-based sensors are emerging as simple, low-cost, portable, and disposable analytical tools for development of green POC devices (GPOCDs). Capabilities of passive fluid transportation, compatibility with biochemical analytes, disposability and high degree of tunability using vivid device fabrication strategies enables development of highly sensitive and economically feasible POC sensors in particularly post COVID-19 pandemic outbreak.
View Article and Find Full Text PDFACS Sens
December 2024
General Surgery Department, Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou 310052, China.
Rapid and multiplexed detection of biomarkers plays an indispensable role in disease diagnosis. Although paper-based lateral flow immunoassays have been widely used in this field, the speediness and throughput are still challenging issues. Herein, an electrochemical vertical flow immunoassay device (eVFID) is fabricated for rapid, ultrasensitive, and multiplexed detection of inflammatory biomarkers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!