Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: For initial respiratory management, continuous positive airway pressure (CPAP) is increasingly used for preterm infants, especially for gestational age less than 32 weeks. However, neonatologists are concerned about the potential risks of CPAP support failure.
Objectives: To examine the association between different initial respiratory support modalities and the outcomes of preterm infants at <32 weeks of gestation across multiple neonatal intensive care units (NICU) in China.
Methods: This study was carried out over a period of 12 months in 2018. Unadjusted relative risks (RR) for demographic and clinical characteristics were calculated for CPAP failure and CPAP success in the total cohort using log-linear model based on generalised estimating equations for clustered observations.
Results: Among 1560 preterm infants delivered at <32 weeks, the incidence of CPAP failure was 10.3%. After adjustment for demographic and clinical factors, the relative risk of mortality (RR 7.54, 95% CI 5.56, 10.44), pneumothorax (RR 9.85, 95% CI 2.89, 61.53), pulmonary haemorrhage (RR 7.78, 95% CI 4.51, 14.64) and BPD (RR 3.65, 95% CI 3.65, 4.51) were considerably higher for infants in the CPAP failure group than those in the CPAP-S group. However, the risk of poor outcomes in CPAP failure infants was similar to that of those in the initial mechanical ventilation (MV) group.
Conclusions: Continuous positive airway pressure failure was associated with an increased risk of mortality and major morbidities, including BPD, pulmonary haemorrhage and pneumothorax, and was comparable to the risk associated with initial MV.