A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance testing and comparative study of natural radioactivity in soil samples using high purity germanium (HPGe) detector. | LitMetric

AI Article Synopsis

  • High Purity Germanium (HPGe) detectors are effective for measuring radionuclides with excellent energy resolution, making them suitable for nuclear techniques.
  • An inter-comparison exercise between Burkina Faso's ARSN and Ghana's RPI-GAEC laboratories was conducted to evaluate the accuracy and reliability of soil sample measurements.
  • The study utilized statistical performance indicators like z-score, precision, trueness, and relative bias, with acceptable precision set at 20% and maximum bias at 15% for radionuclide analysis.

Article Abstract

High Purity germanium (HPGe) detectors are found to be suitable for nuclear techniques for measuring radionuclides with very good energy resolution. Inter-comparison exercise is an important tool for external quality control that enables determination of the accuracy and uncertainty of detector measurement system. In this work, a comparative study of natural radioactivity in soil samples was conducted between the laboratory of Autorité nationale de Radioprotection et de Sûreté Nucléaire (ARSN), Burkina Faso and the laboratory of Radiation Protection Institute of Ghana Atomic Energy Commission (RPI-GAEC),Ghana to ascertain the reliability and accuracy of measurements made in Burkina Faso. For this purpose:•Some replicate soil samples, assumed as proficiency test samples, were analyzed on both the High Purity Germanium detector of ARSN and RPI.•The statistical performance indicators of z-score, precision, trueness and relative bias were used for the evaluation. The limit for acceptable precision and the maximum acceptable bias for all the radionuclides were set to 20% and 15% respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374471PMC
http://dx.doi.org/10.1016/j.mex.2021.101397DOI Listing

Publication Analysis

Top Keywords

soil samples
12
high purity
12
purity germanium
12
comparative study
8
study natural
8
natural radioactivity
8
radioactivity soil
8
germanium hpge
8
burkina faso
8
performance testing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!