MethodsX
Department of Clinical Neurosciences, Cambridge Biomedical Campus, University of Cambridge, CB2 0QQ, UK.
Published: April 2021
Electroencephography (EEG) recordings from CI listeners are contaminated by electrical artefacts that make it difficult to extract neural responses. Previously, we have removed these artefacts by means of interpolation and spatial filtering. However, the extent to which this method can effectively reduce electrical artefacts has not been fully investigated. Here, we assessed the effectiveness of interpolation and spatial filtering to remove electrical artefacts using recordings from a human head specimen implanted with a CI.•Electrical artefacts were obtained using amplitude-modulated (AM'ed) pulse trains presented at several pulse rates (100-to-902 pps) or using high rate pulse trains (902 pps) in which either a pair of electrodes or AM frequencies alternated periodically at a rate of 1Hz.•By adding auditory change complex (ACC), auditory steady-state response (ASSR), or auditory change following response (AC-FR) template waveforms to the contaminated recordings, we show that interpolation allows for effective artefact removal for pulse rates below 400 pps whilst interpolation and spatial filtering are effective at higher pulse rates, with minimal distortions for ACC and AC-FR, and with a degree of amplitude- and phase-distortions for ASSR.•Recordings from CI listeners agreed with simulations, demonstrating that reliable responses can be recovered.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374497 | PMC |
http://dx.doi.org/10.1016/j.mex.2021.101369 | DOI Listing |
Chemosphere
January 2025
Ramboll, 3401 Enterprise Place, Suite 340, Beachwood, Ohio 44122, USA. Electronic address:
Egg injection has been used for decades to determine embryonic mortality and developmental effects of chemical exposures in birds. Specific egg injection methods affect how well these studies replicate the process of chemical delivery to the embryo via maternal deposition, yet few data are available to compare exposure-response relationships between egg injection and maternal transfer studies. This information gap creates uncertainty when considering egg injection studies for assessment of potential adverse effects in wild birds.
View Article and Find Full Text PDFComput Biol Med
January 2025
Laboratory of Metrology and Information Processing, Physics Department, Faculty of Sciences, Ibn Zohr University, Agadir, Morocco.
Surface electromyography (sEMG), a non-invasive technique, offers the ability to identify insights into the activities of muscles in the form of electrical pulses. During the process of recording, the sEMG signals frequently become contaminated by a multitude of different artifacts, the origin of which may be attributed to numerous sources. These artifacts affect the reliability and accuracy of the pure sEMG activity, and subsequently reduce the quality of analysis and interpretation.
View Article and Find Full Text PDFNpj Flex Electron
October 2024
Thayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
The integration of flexible electronics and photonics has the potential to create revolutionary technologies, yet it has been challenging to marry electronic and photonic components on a single polymer device, especially through high-volume manufacturing. Here, we present a robust, chiplet-level heterogeneous integration of polymer-based circuits (CHIP), where several post-fabricated, ultrathin, polymer electronic, and optoelectronic chiplets are vertically bonded into one single chip at room temperature and then shaped into application-specific form factors with monolithic Input/Output (I/O). As a demonstration, we applied this process and developed a flexible 3D-integrated optrode with high-density arrays of microelectrodes for electrical recording and micro light-emitting diodes (μLEDs) for optogenetic stimulation while with unprecedented integration of additional temperature sensors for bio-safe operations and shielding designs for optoelectronic artifact prevention.
View Article and Find Full Text PDFSci Adv
January 2025
Electrical and Computer Engineering Department, University of California, Los Angeles, CA 90095, USA.
Gram staining has been a frequently used staining protocol in microbiology. It is vulnerable to staining artifacts due to, e.g.
View Article and Find Full Text PDFJ Clin Med
December 2024
Section Cochlear Implantation, Department of Otorhinolaryngology, University Hospital of Munich (LMU), 81377 Munich, Germany.
: Before a cochlear implant is considered, patients undergo various audiological tests to assess their suitability. One key test measures the auditory brainstem response (ABR) to acoustic stimuli. However, in some cases, even with maximum sound stimulation, no response is detected.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.