Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
One of the aspects considered about the presence of contaminants in the aquatic ecosystems is their possible effect on critically endangered species, as the case of European eel, . However, there is a lack of analytical methods to determine these contaminants due to the complexity of eel matrix (contains 5-20 % of lipids and 5-15 % of proteins). Thus, a multi-residue method using QuEChERS extraction a clean-up based on new specific sorbents (to eliminate lipids) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed to determine a mix of 21 contaminants. Compared to the previously reported methods (Degani et al., 1986), which were developed for mussels, in this study, one of the proposed extraction methods were adapted to different fish tissues of higher complexity, such as liver and muscle of .•The effectivity of dispersive solid phase extraction (dSPE) using new specific Enhanced Matrix Removal (EMR-lipid) as clean-up for lipid removal was tested.•Clean extracts of matrices with high protein (5-15 %) and lipid (5-20 %) content were obtained ensuring robustness and durability of the analytical systems.•Emerging contaminants extractable by this procedure comprise four different families (pesticides, perfluoroalkyl substances (PFASs), pharmaceuticals and drugs of abuse). Then, it could be further applied to wide scope screening strategies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374397 | PMC |
http://dx.doi.org/10.1016/j.mex.2021.101342 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!