A 41 year-old male that presented after a fall downstairs and the initial imaging was misinterpreted, missing a subtle abnormality, C5/6 subluxation. The patient presented later with neck pain and further imaging demonstrated bilateral facet dislocation with severe deformity requiring 360 spinal fixation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8371150PMC
http://dx.doi.org/10.1016/j.radcr.2021.07.036DOI Listing

Publication Analysis

Top Keywords

bilateral facet
8
facet dislocation
8
dislocation severe
8
severe deformity
8
deformity requiring
8
requiring 360
8
missed cervical
4
cervical spine
4
spine subluxation
4
subluxation leading
4

Similar Publications

Study Design: Retrospective cohort study.

Objectives: To explore the correlation between Facet Tropism (FT) and OPLL in cervical spine.

Methods: One-hundred patients with OPLL of cervical spine and one-hundred normal participants without OPLL or cervical disc herniation were included in this study, the patients were matched to the normal participants respectively based on the same sex and similar age (±5).

View Article and Find Full Text PDF

Purpose: This study aimed to compare the incidence of radiological adjacent segment disease (R-ASD) at L3/4 between patients with L4/5 degenerative spondylolisthesis (DS) who underwent L4/5 posterior lumbar interbody fusion (PLIF) and those who underwent microscopic bilateral decompression via a unilateral approach (MBDU) at L4/5. Our ultimate goal was to distinguish the course of natural lumbar degeneration from fusion-related degeneration while eliminating L4/5 decompression as a confounder.

Methods: Ninety patients with L4/5 DS who underwent L4/5 PLIF (n = 53) or MBDU (n = 37) and were followed for at least 5 years were retrospectively analyzed.

View Article and Find Full Text PDF

Two convex polyhedra that markedly resemble the head of the flatback sea turtle hatchling are identified. The first example is a zygomorphic tetragonal dodecahedron, while the other, an even better matching structure, is a related tetradecahedron, herein speculated to arise from this particular dodecahedron via known mechanisms gleaned from studies of the behavior of foams. A segmented, biomorphic, convex polyhedral model to address cephalic topology is thus presented stemming from solid geometry, anatomical observations, and a recently computed densest local packing arrangement of fifteen slightly oblate spheroids in which fourteen oblate spheroids surround a central such spheroid.

View Article and Find Full Text PDF

This video presents a case of L4-5 unstable spondylolisthesis treated with full-endoscopic transforaminal lumbar interbody fusion (Endo-TLIF), emphasizing the GUARD (Glider Used as a Rotary Device) technique for nerve root protection. This innovative approach involves controlled rotation of the cage glider before cage insertion to minimize the risk of nerve root injury, a significant complication in Endo-TLIF procedures. The GUARD technique, validated in previous cadaveric studies, provides enhanced safety during cage insertion by protecting the nerve root.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the biomechanical effects of different internal fixation techniques for high-grade L5-S1 spondylolisthesis, focusing on how stiffness and hardware stress impact outcomes.
  • A finite element model of the lumbar spine was created to simulate high-grade spondylolisthesis and assess three treatment methods: anterior plate system (APS), bilateral pedicle screw system (BPSS), and transdiscal screw system (TSS).
  • Results showed that while all treatments reduced range of motion, TSS had the best resistance to shear forces and lower internal fixation stress, although it increased stress on the adjacent annulus compared to APS and BPSS.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!