Purpose: To compare the commonly used formulas for intraocular lens (IOL) selection using IOLMaster700 (Carl Zeiss Meditec) and to evaluate the Barrett Universal II (BU-II) formula accuracy when using the Vivinex™ iSert XY1 IOL (Hoya Corporation Medical Division).
Methods: A retrospective chart review was performed that included patients who underwent uneventful cataract surgery with in-the-bag insertion of Vivinex™ iSert XY1 IOL. Prediction errors at 3 months postoperative of IOLMaster 700 with Haigis, Holladay 1, SRK/T, and BU-II formulas were compared. As a subgroup analysis, we focused on the axial length (AL) and IOL power. AL subgroup analysis was based on the following AL subgroups: short (<22.5 mm), medium (22.5-25.5 mm), and long (>25.5 mm). IOL power subgroup analysis was based on the following IOL power subgroups: low (≤18.0 diopters [D]), medium (18.5-24.0 D), and high (≥24.5 D).
Results: This study included 590 eyes of 590 patients. Overall, the four IOL calculation formulas appeared to be similarly accurate. In the long AL subgroup, the BU-II formula had a significantly lower absolute error (AE) than the Holladay 1 formula. In the low-power subgroup, the BU-II formula had a significantly lower AE than the Holladay 1 and SRK/T formulas. On the other hand, in the high-power subgroup, the BU-Ⅱ formula was significantly less accurate than the SRK/T formula and also appeared to be worse than the Holladay 1 formula (P = 0.052).
Conclusion: The BU-II formula might be less accurate when using a Vivinex™ iSert XY1 IOL of 24.5 D or greater.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8544088 | PMC |
http://dx.doi.org/10.4103/ijo.IJO_3455_20 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!