Background: Timely diagnosis and early initiation of life-saving antiretroviral therapy are critical factors in preventing mortality among HIV-infected infants. However, resource-limited settings experience numerous challenges associated with centralised laboratory-based testing, including low rates of testing, complex sample referral pathways and unacceptably long turnaround times for results. Point-of-care (POC) HIV testing for HIV-exposed infants can enable same-day communication of results and early treatment initiation for HIV-infected infants. However, complex operational issues and service integration can limit utility and must be well understood prior to implementation. We explored and documented the challenges and enabling factors in implementing the POC Xpert® HIV-1 Qual test (Cepheid, Sunnyvale, CA, USA) for early infant diagnosis (EID) as part of routine services in four public hospitals in Myanmar.

Methods: This sub-study was part of a randomised controlled stepped-wedge trial (Australian and New Zealand Clinical Trials Registry, number 12616000734460) designed to investigate the impact of POC testing for EID in Myanmar and Papua New Guinea. Infants recruited during the intervention phase underwent POC testing at the participating hospitals as part of routine care. Semi-structured interviews with 23 caregivers, 12 healthcare providers and 10 key informants were used to explore experiences of POC-EID testing. The research team and hospital staff documented and discussed implementation challenges throughout the study.

Results: Overall, caregivers and healthcare workers were satisfied with the short turnaround time of the POC test. Occasional delays in POC testing were mostly attributable to late receipt of samples by laboratory technicians and communication constraints among healthcare staff. Hospital staff valued technical assistance from the research group and the National Health Laboratory. Despite staff shortages and infrastructure challenges such as unreliable electricity supply and cramped space, healthcare workers and caregivers found the implementation of the POC test to be feasible at pilot sites.

Conclusions: As plans for national scale-up evolve, there needs to be a continual focus on staff training, communication pathways and infrastructure. Other models of care, such as allowing non-laboratory-trained personnel to perform POC testing, and cost effectiveness should also be evaluated.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8383426PMC
http://dx.doi.org/10.1186/s12913-021-06797-3DOI Listing

Publication Analysis

Top Keywords

poc testing
16
early infant
8
infant diagnosis
8
hiv-infected infants
8
testing
8
poc
8
caregivers healthcare
8
hospital staff
8
healthcare workers
8
poc test
8

Similar Publications

Point-of-Care Potassium Measurement vs Artificial Intelligence-Enabled Electrocardiography for Hyperkalemia Detection.

Am J Crit Care

January 2025

Shih-Hua Lin is a professor, Division of Nephrology, Department of Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei.

Background: Hyperkalemia can be detected by point-of-care (POC) blood testing and by artificial intelligence- enabled electrocardiography (ECG). These 2 methods of detecting hyperkalemia have not been compared.

Objective: To determine the accuracy of POC and ECG potassium measurements for hyperkalemia detection in patients with critical illness.

View Article and Find Full Text PDF

Advancing microfluidic point-of-care platelet function tests: opportunities and challenges from bench to market.

Front Bioeng Biotechnol

December 2024

George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States.

Platelets are critical for blood clotting, with shear-induced platelet aggregation (SIPA) playing a key role in hemostasis and the prevention of excessive bleeding. SIPA function potentially leads to life-threatening diseases such as hemorrhage and myocardial infarction, which are leading causes of death globally. Point-of-care platelet function tests (POC PFTs) are developed to assess platelet dysfunction and distinguish between normal and abnormal platelet activity.

View Article and Find Full Text PDF

Overview of Gas-Generating-Reaction-Based Immunoassays.

Biosensors (Basel)

November 2024

College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.

Point-of-care (POC) immunoassays have become convincing alternatives to traditional immunosensing methods for the sensitive and real-time detection of targets. Immunoassays based on gas-generating reactions were recently developed and have been used in various fields due to their advantages, such as rapid measurement, direct reading, simple operation, and low cost. Enzymes or nanoparticles modified with antibodies can effectively catalyze gas-generating reactions and convert immunorecognition events into gas pressure signals, which can be easily recorded by multifunctional portable devices.

View Article and Find Full Text PDF

Rapid and Visual Detection of Urinary Pathogens by Employing Bifunctional Deoxyribonucleic Acid Sensors and Aggregation of Gold Nanoparticles.

Anal Chem

December 2024

NMPA Key Laboratory for Research and Evaluation of Drug Metabolism & Guangdong Provincial Key Laboratory of New Drug Screening & Guangdong-Hongkong-Macao Joint Laboratory for New Drug Screening, School of Pharmaceutical Sciences, Southern Medical University, Guangzhou 510515, China.

A simple, rapid, and visual approach is developed to perform diagnosis of urinary tract infection (UTI) and antimicrobial susceptibility testing (AST) by employing smart bifunctional DNA (bfDNA) sensors, exonuclease III, concatermers of CuO nanoparticles (CuONPs), and gold NPs (AuNPs) aggregation [AuNPs agglutination (AA)], namely, the bfDEC-AA method. The bfDNA sensors serve as probes for identifying 16S rRNA genes of bacterium or 18S rRNA of fungus and as mediators connecting the concatermers of CuONPs. The AA as a signal source is triggered by Cu(I)-catalyzed azide-alkyne cycloaddition click chemistry.

View Article and Find Full Text PDF

A novel Alzheimer detection rapid-testing low-cost technique by a gate engineered gate stack dual-gate FET device.

Talanta

December 2024

Nextgen Adaptive Systems Group, Department of Electrical Engineering, National Institute of Technology Patna, Bihar, India. Electronic address:

This study explores a quick, low-cost method to detect Alzheimer's disease (AD) by evaluating the accomplishment of a Gate-Stack (GS) Field Effect Transistor (FET). We investigate Single-Metal (SM), Dual-Metal (DM), and Tri-Metal Double Gate (DG) configurations, where cavities have been created by etching the oxide layer underneath the gate to immobilize grey matter samples collected through Solid-phase microextraction (SPME). Healthy and AD-affected grey matter have different dielectric characteristics at high frequencies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?