Objectives: This study aimed to assess the anatomical leaflet variation and investigate its impact on the procedural outcome in patients undergoing transcatheter edge-to-edge tricuspid repair.
Background: Tricuspid regurgitation (TR) is associated with a poor prognosis.
Methods: The study participants were consecutive patients who underwent transcatheter edge-to-edge tricuspid repair with the MitraClip, TriClip, or PASCAL systems from June 2015 to July 2020 at the Bonn Heart Center. The tricuspid leaflet morphologies were imaged using 2-dimensional and 3-dimensional transesophageal echocardiography. The severity of TR was assessed according to the 5-grade scheme. The primary endpoint was residual TR ≥3+ within 30 days.
Results: Of the 145 study participants, 103 (71.1%) participants were categorized as the 3-leaflet configuration, while 42 (28.9%) were categorized as the 4-leaflet configuration. Successful device implantation was achieved in 136 (93.8%) patients, with no statistical difference between the 3-leaflet and 4-leaflet configuration groups. However, compared with patients with a 3-leaflet configuration, patients with 4-leaflet configuration more frequently had residual TR ≥3+ (18.4% vs 38.1%; P = 0.018). In the multivariable model, the 4-leaflet configuration was associated with an increased risk of residual TR ≥3+ (odds ratio: 2.65; 95% CI 1.15-6.10; P = 0.022), independent of baseline TR grade, coaptation gap width, and TR jet location. After 1-year follow-up, compared with patients with residual TR <3+, patients with residual TR ≥3+ had a significantly higher incidence of the composite of all-cause mortality or heart failure hospitalization (27.7% vs 56.1%; P = 0.016).
Conclusions: A 4-leaflet configuration of the tricuspid valve is observed in approximately one-third of patients undergoing transcatheter edge-to-edge tricuspid repair, which is associated with an increased risk of residual TR after the procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcin.2021.07.048 | DOI Listing |
JACC Cardiovasc Interv
October 2021
Heart Center Bonn, Department of Medicine II, University Hospital Bonn, Bonn, Germany. Electronic address:
Objectives: This study aimed to assess the anatomical leaflet variation and investigate its impact on the procedural outcome in patients undergoing transcatheter edge-to-edge tricuspid repair.
Background: Tricuspid regurgitation (TR) is associated with a poor prognosis.
Methods: The study participants were consecutive patients who underwent transcatheter edge-to-edge tricuspid repair with the MitraClip, TriClip, or PASCAL systems from June 2015 to July 2020 at the Bonn Heart Center.
Diagnostics (Basel)
May 2021
HEART-Heart Embryology and Anatomy Research Team, Department of Anatomy, Jagiellonian University Medical College, 31-007 Cracow, Poland.
The right atrioventricular valve (RAV) is an important anatomical structure that prevents blood backflow from the right ventricle to the right atrium. The complex anatomy of the RAV has lowered the success rate of surgical and transcatheter procedures performed within the area. The aim of this study was to describe the morphology of the RAV and determine its spatial position in relation to selected structures of the right atrium.
View Article and Find Full Text PDFJACC Cardiovasc Interv
January 2019
Visible Heart Laboratory, Departments of Biomedical Engineering and Surgery, University of Minnesota, Minneapolis, Minnesota; Institute for Engineering in Medicine, University of Minnesota, Minneapolis, Minnesota.
Objectives: The authors aimed to comprehensively detail the right atrioventricular valve functional leaflet anatomies.
Background: The rapid development of both surgical and percutaneous repair techniques for tricuspid regurgitation has renewed interest in variations in the morphology of the right atrioventricular valve.