This study aims to estimate the entrance surface dose (ESD) of a water phantom for kilovoltage x-ray beams using an air kerma area product meter (KAP meter) equipped in an x-ray unit. The KAP meter was calibrated in terms of the ESD determined by a plane-parallel ionization chamber based on a 60Co absorbed dose-to-water calibration coefficient, ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$. The ESD measured using the KAP meter was verified by comparing it with that estimated by the air kerma calibration coefficient, NK, for x-ray beam qualities. The ratio of ESDs based on ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$ and NK was 1.003 on average and independent of the beam quality. The ESD by the KAP meter was an agreement within ±1.5% with that measured using the plane-parallel chamber for 10 × 10-30 × 30 cm2 fields with a source-surface distance of 75-150 cm. It was possible to estimate the ESD directly in a water phantom for x-ray beams without correction factors compared to the existing air kerma calibration, using a KAP meter calibrated based on ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/ncab122 | DOI Listing |
J Med Radiat Sci
March 2024
Department of Forensic Medicine, Monash University, Melbourne, Victoria, Australia.
Introduction: Diagnostic reference levels (DRLs) are typical dose levels for medical imaging examinations for groups of standard-sized patients or standard phantoms for broadly defined types of equipment used as a tool to aid optimisation of protection for medical exposures. Currently, there are no paediatric DRLs for conventional radiography (i.e.
View Article and Find Full Text PDFPhys Med
August 2023
HUS Diagnostic Center, Radiology, University of Helsinki and Helsinki University Hospital, Finland.
Cone beam computed tomography (CBCT) may provide essential additional image guidance to endovascular abdominal aneurysm repair (EVAR) operations but also significant radiation exposure to patients if scans are not carefully optimized. The purpose of our study was to define the image quality requirements for intraoperative EVAR CBCT imaging and to optimize the CBCT exposure parameters accordingly. A Multi-Energy CT phantom simulating a large patient was used by replacing the central phantom cylinder with a custom water-filled insert including an EVAR stent.
View Article and Find Full Text PDFRadiat Prot Dosimetry
March 2022
Ankara University, Institute of Nuclear Sciences, 06100 Ankara, Turkey.
This study aims to determine the radiation doses of patients and staff during different interventional radiology and cardiology examinations. Dose measurements for interventional radiology examinations were performed in Ibn-i Sina Hospital of Ankara University using Siemens Artis-Zee medical imaging system. Patient dose measurement was carried out for interventional cardiology examinations in Cardiology Department of TOBB-ETU University, Medical Faculty Hospital using Philips Allura Centron interventional X-ray system.
View Article and Find Full Text PDFJ Appl Clin Med Phys
December 2021
Faculty of Health Sciences, Department of Quantum Medical Technology, Kanazawa University, Ishikawa, Japan.
Purpose: This study aimed to evaluate the effect of equalization filters (EFs) on the kerma-area product ( ) and incident air-kerma ( ) using a kerma-area product (KAP) meter. In addition, potential underestimations of the values by EFs were identified.
Materials And Methods: A portable flat-panel detector (FPD) was placed to measure the X-ray beam area (A) and EFs dimension at patient entrance reference point (PERP).
Radiat Prot Dosimetry
September 2021
SAGA Heavy Ion Medical Accelerator in Tosu, 3049 Harakogamachi, Tosu, Saga, 841-0071, Japan.
This study aims to estimate the entrance surface dose (ESD) of a water phantom for kilovoltage x-ray beams using an air kerma area product meter (KAP meter) equipped in an x-ray unit. The KAP meter was calibrated in terms of the ESD determined by a plane-parallel ionization chamber based on a 60Co absorbed dose-to-water calibration coefficient, ${N}_{D,w}^{{}^{60}\mathrm{C}\mathrm{o}}$. The ESD measured using the KAP meter was verified by comparing it with that estimated by the air kerma calibration coefficient, NK, for x-ray beam qualities.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!