The impact of graphene oxide sheet lateral dimensions on their pharmacokinetic and tissue distribution profiles in mice.

J Control Release

Nanomedicine Lab, National Graphene Institute, Faculty of Biology, Medicine & Health, University of Manchester, AV Hill Building, Manchester M13 9PT, United Kingdom; Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain. Electronic address:

Published: October 2021

AI Article Synopsis

  • The study investigates how different sizes of graphene oxide (GO) affect their behavior in living systems, focusing on their pharmacokinetics.
  • Researchers functionalized GO with a radiometal chelator for imaging, discovering that larger GO particles accumulated in the lungs, while all sizes were excreted through urine.
  • Findings suggest that while the thickness of nanomaterials primarily influences excretion, the rate of urinary excretion does vary with the size of the GO particles.

Article Abstract

Although the use of graphene and 2-dimensional (2D) materials in biomedicine has been explored for over a decade now, there are still significant knowledge gaps regarding the fate of these materials upon interaction with living systems. Here, the pharmacokinetic profile of graphene oxide (GO) sheets of three different lateral dimensions was studied. The GO materials were functionalized with a PEGylated DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid), a radiometal chelating agent for radioisotope attachment for single photon emission computed tomography (SPECT/CT) imaging. Our results revealed that GO materials with three distinct size distributions, large (l-GO-DOTA), small (s-GO-DOTA) and ultra-small (us-GO-DOTA), were sequestered by the spleen and liver. Significant accumulation of the large material (l-GO-DOTA) in the lungs was also observed, unlike the other two materials. Interestingly, there was extensive urinary excretion of all three GO nanomaterials indicating that urinary excretion of these structures was not affected by lateral dimensions. Comparing with previous studies, we believe that the thickness of layered nanomaterials is the predominant factor that governs their excretion rather than lateral size. However, the rate of urinary excretion was affected by lateral size, with large GO excreting at slower rates. This study provides better understanding of 2D materials in vivo behaviour with varying structural features.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jconrel.2021.08.028DOI Listing

Publication Analysis

Top Keywords

lateral dimensions
12
urinary excretion
12
graphene oxide
8
excretion lateral
8
lateral size
8
materials
6
lateral
5
impact graphene
4
oxide sheet
4
sheet lateral
4

Similar Publications

Aim: The tubercle of Zuckerkandl (TZ) is considered to be the fusion point of the ultimabranchial body and the median thyroid body. We aimed to evaluate the frequency of TZ and its relationship with other anatomical variations and recurrent laryngeal nerve (RLN) paralysis.

Material And Methods: Data regarding the thyroid lobe and RLN of patients with thyroidectomy between June 2016 and December 2019 were retrospectively evaluated.

View Article and Find Full Text PDF

Purpose: Sulcus-deepening trochleoplasty (TP) effectively treats patellofemoral (PF) instability (PFI) caused by high-grade trochlear dysplasia (TD), but current evidence is based on small case series. We hypothesised, that TP would result in significant functional improvements and a low re-dislocation rate but would not accelerate the progression of PF cartilage deterioration.

Methods: We retrospectively reviewed all TP cases performed by a single surgeon between 2015 and 2021.

View Article and Find Full Text PDF

Ultrasonography is a reliable imaging technique for the accurate diagnosis and evaluation of musculoskeletal disorders. Recent developments in ultrasound technology have significantly increased image resolution, making it possible to see anatomical features at almost microscopic dimensions. Current standards for standardized shoulder ultrasonography mostly depend on outdated machine types and configurations that may not fully utilize these high-resolution imaging capabilities.

View Article and Find Full Text PDF

Dimensions and position of the eye for facial approximations in a South African cone beam computed tomography sample.

J Forensic Sci

December 2024

Anatomy and Histology Department, School of Medicine, Faculty of Health Sciences, Sefako Makgatho Health Sciences University, Ga-Rankuwa, Gauteng, South Africa.

Accurate population and sex-specific normative values for the orbital and ocular dimensions, including the position and protrusion of the eye relative to the orbital rim, are vital for reliable facial approximations. In studies utilizing cadaveric tissue and computed tomography scans, the observed measurements may be influenced by desiccation, distortion or gravity, respectively. This study assessed the dimensions of the eye and orbit and established the position and protrusion of the eye relative to the orbital margin using cone beam computed tomography (CBCT) scans to negate the effect of gravity in the supine position.

View Article and Find Full Text PDF

Background: The Mustard and Senning operations for dextro-transposition of the great arteries (D-TGA) establish a biventricular physiology with a subaortic right ventricle (sRV). While prolonged QRS has been associated with worse prognosis in these patients, current echocardiographic tools fall short in adequately assessing the (mal)performance and function decline of the sRV during follow-up. The present study is the first to characterize Myocardial Work (MW) indices of the sRV in D-TGA patients after Mustard/Senning repair.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!