Introduction: A successful integration of automated blood sampling (ABS) into the telemetry instrumented canine cardiovascular model is presented in this study. This combined model provides an efficient means to quickly gain understanding of potential effects on key cardiovascular parameters in dog while providing a complete Pharmacokinetic/Pharmacodynamic (PK/PD) profile for discovery compounds without handling artifacts, reducing the need for a separate pharmacokinetic study.

Methods: Male beagle dogs were chronically implanted with telemetry devices (PhysioTel™ model D70-PCTP) and vascular access ports (SPMID-GRIDAC-5NC). BASi Culex-L automated blood sampling (Bioanalytical Systems, Inc) system was used to collect blood samples at multiple time points. A series of four use cases utilizing four different test compounds and analytical endpoints are described to illustrate some of the potential applications of the technique.

Results: In the four presented use cases, automated blood sampling in telemetry instrumented dogs provides simultaneous cardiovascular (heart rate, arterial blood pressure, and left ventricular pressure), electrophysiological assessment (QTc, PR, and QRS intervals), body temperature, and animal activity, while collecting multiple blood samples for drug analysis.

Conclusion: The combination of automated blood sampling with cardiovascular telemetry monitoring is a novel capability designed to support safety pharmacology cardiovascular assessment of discovery molecules. By combining telemetry and high-fidelity ABS, the model provides an enhanced PK/PD understanding of drug-induced hemodynamic and electrocardiographic effects of discovery compounds in conscious beagles in the same experimental session. Importantly, the model can reduce the need for a separate pharmacokinetic study (positive reduction 3R impact), reduces compound syntheses requirements, and shorten development timelines. Furthermore, implementation of this approach has also improved animal welfare by reducing the animal handling during a study, thereby reducing stress and associated data artifacts (positive refinement 3R impact).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.vascn.2021.107109DOI Listing

Publication Analysis

Top Keywords

automated blood
20
blood sampling
20
telemetry instrumented
8
discovery compounds
8
separate pharmacokinetic
8
blood samples
8
blood
7
telemetry
6
cardiovascular
6
automated
5

Similar Publications

Background: Insulin pumps coupled with continuous glucose monitoring sensors use algorithms to analyze real-time blood glucose levels. This allows for the suspension of insulin administration before hypoglycemic thresholds are reached or for adaptive tuning in hybrid closed-loop systems. This longitudinal retrospective study aims to analyze real-world glycemic outcomes in a pediatric population transitioning to such devices.

View Article and Find Full Text PDF

Acute Responses of Low-Load Resistance Exercise with Blood Flow Restriction.

J Funct Morphol Kinesiol

December 2024

Patriot Performance Laboratory, Frank Pettrone Center for Sports Performance, George Mason University, Fairfax, VA 22030, USA.

Blood flow restriction (BFR) is a popular resistance exercise technique purported to increase metabolic stress and augment training adaptations over time. However, short-term use may lead to acute neuromuscular fatigue and higher exertion ratings. The purpose of the current study was to examine acute physiological responses to low-load resistance exercise utilizing BFR compared to higher-load, non-BFR resistance exercise.

View Article and Find Full Text PDF

Objective: to investigate the reciprocal impact on the genome of malignant and normal human peripheral bloodlymphocytes under their co-culture and the possibility to modify the effects by astaxanthin.

Methods: Separate and joint/separate culturing of peripheral blood lymphocytes (PBL) of the chronic lymphocyticleukemia (CLL) patients (n = 6) and conditionally healthy individuals (n = 6), Comet assay method, fluorescencemicroscopy with automated software for the analysis of results, statistical methods.

Results: Both direct and rescue tumour-induced bystander effects were observed under the joint/separate culturing of blood lymphocytes of conditionally healthy individuals (the bystander cells) and blood cells from CLL patients(the inducer cells).

View Article and Find Full Text PDF

Background And Purpose: External drainage represents a well-established treatment option for acute intracerebral hemorrhage. The current standard of practice includes post-operative computer tomography imaging, which is subjectively evaluated. The implementation of an objective, automated evaluation of postoperative studies may enhance diagnostic accuracy and facilitate the scaling of research projects.

View Article and Find Full Text PDF

Introduction: Intravenous iron sucrose (IVIS) is a rapidly acting, safe, and effective treatment for moderate anemia among pregnant women. The effectiveness of IVIS at 6 months post IVIS infusion was unknown. We, therefore, assessed the mean increase in hemoglobin concentration and body iron replenishment status at 6 months after the last dose of IVIS infusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!