A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Implications of Virtual CBCT-Based Immediate Implant Planning for Maxillary and Mandibular First Molars. | LitMetric

Implications of Virtual CBCT-Based Immediate Implant Planning for Maxillary and Mandibular First Molars.

J Oral Implantol

Department of Maternal and Child Health, School of Public Health, Peking University, Beijing, P.R. China.

Published: October 2022

The purpose of his study was to investigate the projected ridge-implant dimensions derived from virtual superimposition of implants on intact first molars mimicking immediate implantation in the mandible (Md1) and maxilla (Mx1) using cone-beam computed tomography (CBCT). The CBCT records of 41 patients (19 males and 22 females) with Md1 or Mx1 were collected. Ten-millimeter-long cylindrical implants with different diameters were virtually positioned at prosthetically ideal angles into interradicular septum using CBCT software. Radiographic alveolar ridge height (ARH), alveolar ridge width (ARW), gap distance, and vertical distance from the implant platform to the alveolar crest were measured. Twenty Mx1s (48.8%) and 21 Md1s (51.2%) were included. The mean ARH values were 7.13 ± 4.32 and 15.64 ± 1.80 mm for Mx1 and Md1, respectively; 87.8% of mesiobuccal sites had gap distance of >2 mm when 6-mm-diameter implants were used. Increasing implant diameter from 6 to 9 mm decreased the percentage of sites with ARW > 2 mm from 80.5% to 41.5% buccally and from 86.4% to 26.8% lingually. The mean vertical distance from the implant platform to the alveolar crest was 1.41 ± 1.09 mm buccally and 1.11 ± 1.10 mm lingually. Immediate implant placement of first molars, especially in the maxilla, requires stringent presurgical evaluation. Implants no wider than 6 mm placed into the interradicular septum may meet acceptable running room and alveolar plate thickness criteria if the jumping distance is grafted. Further clinical trials are needed to confirm these findings in this virtual study.

Download full-text PDF

Source
http://dx.doi.org/10.1563/aaid-joi-D-20-00397DOI Listing

Publication Analysis

Top Keywords

interradicular septum
8
alveolar ridge
8
gap distance
8
vertical distance
8
distance implant
8
implant platform
8
platform alveolar
8
alveolar crest
8
implant
5
alveolar
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!