A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of remote monitoring on clinical outcomes in European heart failure patients with an implantable cardioverter-defibrillator: secondary results of the REMOTE-CIED randomized trial. | LitMetric

Aims: Remote patient monitoring (RPM) systems offer a promising alternative to conventional In-Clinic check-ups, hereby reducing unnecessary clinic visits. Especially with the rise of the COVID-19 pandemic, this reduction is of paramount importance. Regarding the association between RPM and clinical outcomes, findings of previous studies have been inconsistent. The aim of this study is to elucidate the effect of partly substituting In-Clinic visits by RPM on clinical outcomes in implantable cardioverter-defibrillator (ICD) patients.

Methods And Results: The study included 595 heart failure patients (LVEF ≤35%; NYHA Class II/III) implanted with an ICD compatible with the Boston Scientific LATITUDE™ system. Participants were randomized to RPM plus an annual In-Clinic visit or 3-6 months In-Clinic check-ups alone. The investigated endpoints after 2 years of follow-up included a composite of all-cause mortality and cardiac hospitalization, mortality and cardiac hospitalization as independent endpoints and ICD therapy. The incidence of mortality and hospitalization did not differ significantly as independent, nor as composite endpoint between the RPM and In-Clinic group (all Ps <0.05). The results were similar regarding ICD therapy, except for appropriate ICD therapy (odds ratio 0.50; 95% confidence interval 0.26-0.98; P = 0.04). Exploratory subgroup analyses indicated that the effect of RPM differs between patients with specific characteristics, i.e. ≥60 years and permanent atrial fibrillation (all Ps < 0.05).

Conclusion: RPM is non-inferior to conventional In-Clinic visits regarding clinical outcomes. Routine In-Clinic follow-up may partly be substituted by RPM without jeopardizing safety and efficiency, and thus reducing unnecessary In-Clinic visits.

Clinicaltrials.gov Identifier: NCT01691586.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8499745PMC
http://dx.doi.org/10.1093/europace/euab221DOI Listing

Publication Analysis

Top Keywords

clinical outcomes
12
heart failure
8
failure patients
8
implantable cardioverter-defibrillator
8
in-clinic check-ups
8
rpm clinical
8
mortality cardiac
8
cardiac hospitalization
8
rpm
5
in-clinic
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!