Background: This study assessed the use of and exposure to handheld laser devices by Canadians and the potential associated health risks.
Data And Methods: The 2019 Canadian Community Health Survey collected data from 12,397 Canadians on the prevalence of handheld laser exposure or use, and associated eye or skin injuries.
Results: In 2019, an estimated 12.4% (95% CI: 11.4% to 13.4%) of Canadians reported using a handheld laser device or being exposed to its beam in the previous year, and those between the ages of 12 and 17 represented 30.5% (95% CI: 26.6% to 34.4%) of users. The highest laser device use or exposure was among those with a university education (13.8%; 95% CI: 11.8% to 15.8%), and a significant trend was found over income categories (p < 0.0001). The highest prevalence of exposure or use involved laser pointers (69.4%; 95% CI: 65.4% to 73.4%), followed by laser toys (38.5%; 95% CI: 34.6% to 42.5%), laser torches (8.2%; 95% CI: 6.1% to 10.4%) and-lastly-search-and-rescue lasers (0.8%E; 95% CI: 0.3% to 1.2%). Overall, 0.7%E (95% CI: 0.2% to 1.2%) of Canadians reported discomfort or injury in the past 12 months. One-quarter (27.9%; 95% CI: 23.8% to 31.9%) of users had a laser beam intentionally directed toward their eyes or skin. Most users did not buy the device (56.3%; 95% CI: 52.1% to 60.5%), while 40.5% (95% CI: 36.2% to 44.7%) purchased it at a Canadian retail store or online (3.8%E; 95% CI: 2.6% to 5.0%).
Discussion: The prevalence of handheld laser device use and beam exposure was 12.4% (95% CI: 11.4% to 13.4%), representing approximately 3.9 million Canadians. While the number of reported injuries was low, ongoing surveillance helps assess the effectiveness of current risk management approaches for laser products.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.25318/82-003-x202100800002-eng | DOI Listing |
PLoS One
January 2025
Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom.
Ocular microtremor (OMT) is a fixational eye movement that cannot be seen with the naked eye but is always present, even when the eye appears motionless/still. The link between OMT and brain function provides a strong rationale for investigation as there lies potential for its use as a biomarker in populations with neurological impairments. OMT frequency is typically 70-80Hz in healthy adults and research suggests that this will be reduced in those with neurological disease such as Parkinson's Disease (PD).
View Article and Find Full Text PDFJ Hand Surg Am
January 2025
Hand and Upper Extremity Division of Plastic and Reconstructive Surgery, University of California Davis, Sacramento, CA.
Purpose: Current technologies to define the zone of acute peripheral nerve injury intraoperatively are limited by surgical experience, time, cumbersome electrodiagnostic equipment, and interpreter reliability. In this pilot study, we evaluated a real-time, label-free optical technique for intraoperative nerve injury imaging. We hypothesize that fluorescence lifetime imaging (FLIm) will detect a difference between the time-resolved fluorescence signatures for acute crush injuries versus uninjured segments of peripheral nerves in sheep.
View Article and Find Full Text PDFAppl Spectrosc
December 2024
Nuclear Mission Branch, Air Force Research Laboratory, Kirtland AFB, New Mexico, USA.
This work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity.
View Article and Find Full Text PDFPLoS One
December 2024
Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, The Netherlands.
The demographic shift has increased the demand for surgical interventions to address age-related degenerative diseases, such as spinal fusion. Accurate placement of pedicle screws, crucial for successful spinal fusion, varies widely with physician experience. Integrating tissue sensing into spine surgical instruments allows intraoperative examination of tissue properties, providing surgeons with additional information to prevent screw misplacement.
View Article and Find Full Text PDFJ Vasc Interv Radiol
December 2024
Department of Interventional Radiology, Mallinckrodt Institute of Radiology, 510 S Kingshighway Blvd, St. Louis, MO 63110.
Purpose: To evaluate the primary use of a laser atherectomy-thrombectomy system in patients with acute limb ischemia (ALI).
Materials And Methods: A single-center retrospective review of patients presenting with ALI (14 days or less) from August 2021 to February 2024 treated primarily with a laser atherectomy-thrombectomy system (Auryon; Angiodynamics, Queensbury, New York) was performed. Technical success was defined by resolution of the acute occlusion with adequate inflow and outflow with pedal signals detectable by handheld doppler ultrasound.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!