Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Acquisition of surface electromyography (sEMG) from a person with an amputated lower extremity (LE) during prosthesis-assisted walking remains a significant challenge due to the dynamic nature of the gait cycle. Current solutions to sEMG-based neural control of active LE prostheses involve a combination of customized electrodes, prosthetic sockets, and liners. These technologies are generally: (i) incompatible with a subject's existing prosthetic socket and liners; (ii) uncomfortable to use; and (iii) expensive. This paper presents a flexible dry electrode design for sEMG acquisition within LE prosthetic sockets which seeks to address these issues. Design criteria and corresponding design decisions are explained and a proposed flexible electrode prototype is presented. Performances of the proposed electrode and commercial Ag/AgCl electrodes are compared in seated subjects without amputations. Quantitative analyses suggest comparable signal qualities for the proposed novel electrode and commercial electrodes. The proposed electrode is demonstrated in a subject with a unilateral transtibial amputation wearing her own liner, socket, and the portable sEMG processing platform in a preliminary standing and level ground walking study. Qualitative analyses suggest the feasibility of real-time sEMG data collection from load-bearing, ambulatory subjects.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8365363 | PMC |
http://dx.doi.org/10.1109/BioRob49111.2020.9224338 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!