AI Article Synopsis

  • The study examined the growth of microorganisms in lipid emulsions used for Total Parenteral Nutrition (TPN) when these emulsions are contaminated and left stagnant in a closed infusion device.
  • It was tested whether flushing the device with saline after lipid emulsion infusion could prevent bacterial growth, and results showed that flushing effectively reduced bacteria levels.
  • The findings highlighted that bacterial growth varied based on the infusion device's design and the amount of saline used, emphasizing the importance of proper infusion management to prevent infections.

Article Abstract

We investigated the extent of growth of microorganisms with simultaneous administration of lipid emulsions with infusions for Total Parenteral Nutrition (TPN), assuming that the lipid emulsions contaminated with microorganisms are stagnant in a closed-type infusion device. We also investigated if bacterial growth can be prevented in the infusion device by flushing the inside of the infusion device with saline solution after the administration of lipid emulsion from the side tube setting. We made a preparation by adding to the lipid emulsion and started the infusion simultaneously with the infusion solution for TPN and lipid emulsion with the piggyback method. Immediately after the completion of lipid emulsion infusion, we conducted flushing with saline solution. The volume of saline solution was none, 5, 10, or 20 mL at a flow rate of 1 mL/s. Infusion solution that was stagnant in the infusion device was collected immediately before completing the lipid emulsion infusion and 20 h after flushing, i.e., 24 h after starting the infusion for TPN, and the number of viable bacteria was determined. The number of viable increased in the infusion device of all three species used in this experiment 24 h after starting the lipid emulsion infusion without flushing. We found that bacterial growth could be prevented through flushing with saline solution after the completion of lipid emulsion infusion and flushing out the stagnant infusion solution in the closed-type infusion device. We found that if was present in the closed-type infusion device, it would multiply. We also found that the number of viable bacteria varied according to the variety and internal structure of the closed-type infusion device as well as the liquid volume used for flushing, although flushing can prevent the growth of microorganisms. Proper management and manipulation of infusion is required to prevent infection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8364470PMC
http://dx.doi.org/10.7150/ijms.60200DOI Listing

Publication Analysis

Top Keywords

lipid emulsion
32
infusion device
32
closed-type infusion
20
infusion
19
saline solution
16
emulsion infusion
16
administration lipid
12
infusion solution
12
infusion flushing
12
number viable
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!