Open surgery allows the use of all 6 degrees of freedom (DOF; x-y-z and roll-pitch-yaw), whereas laparoscopy requires working under limitation to 4 axes. We present a prospective experimental study evaluating translational and rotational DOF restriction in surgical suturing tasks. An experimental platform included a kinematic structure that limited the maneuverability of the surgical instruments. The subjects (n=20) worked in a randomized order using (1) 6DOF, (2) 4DOF with 3 translational and 1 rotational DOF (4TRANS), and (3) 4DOF with 1 translational and 3 rotational DOF (4ROT). The time required to perform each task was recorded. Suturing and knot tying were significantly faster under 6DOF compared with 4ROT (both P<0.001) and 4TRANS (both P<0.001). Assessment of subjective difficulty and impairment showed most favorable results for 6DOF. The advantage of rotational compared with translational DOF should be considered in the development of future surgical devices.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SLE.0000000000000961DOI Listing

Publication Analysis

Top Keywords

translational rotational
12
rotational dof
12
degrees freedom
8
surgical suturing
8
prospective experimental
8
experimental study
8
4dof translational
8
reducing degrees
4
freedom surgical
4
suturing implications
4

Similar Publications

Background: The Simple Shoulder Test (SST) is a widely used patient-reported outcome measure for shoulder function. However, there is currently no version of the SST for the Thai population.

Purpose: To cross-culturally adapt and evaluate the reliability and validity of a Thai version of the SST (Thai SST) for patients with shoulder pathologies, using the Thai version of the American Shoulder and Elbow Surgeons (ASES) score as a comparison tool.

View Article and Find Full Text PDF

Radiation-resistant bacteria are of great application potential in various fields, including bioindustry and bioremediation of radioactive waste. However, how radiation-resistant bacteria combat against invading phages is seldom addressed. Here, we present a series of crystal structures of a sensor and an effector of the cyclic oligonucleotide-based anti-phage signaling system (CBASS) from a radioresistant bacterium Deinococcus wulumuqiensis.

View Article and Find Full Text PDF

Objective To establish an automatic reduction method for unilateral zygomatic fractures based on Iterative Closes Point(ICP)algorithm. Material and Methods 60 patients with unilateral type B zygomatic fractures were included. After acquiring CT images, zygomatic fragments were segmented using self-developed software MICSys.

View Article and Find Full Text PDF

Purpose: Our study presents a virtual reality-based tangent screen test (VTS) to measure subjective ocular deviations including torsion in nine directions of gaze. The test was compared to the analogous Harms tangent screen test (HTS).

Methods: We used an Oculus Go controller and head-mounted-display with rotation sensors to measure patient's head orientation for the VTS.

View Article and Find Full Text PDF

Aim: We developed a rapid evaluation scale for pericardiectomy through a 12-lead electrocardiogram (ECG), in order to improve the diagnostic accuracy of pericardiectomy of tuberculous constrictive pericarditis.

Method: In this study, 262 patients with tuberculous constrictive pericarditis (102 patients) and non-tuberculous constrictive pericarditis (160 patients) were selected by convenience sampling method as participants in Hangzhou Red Corss Hospital from January 2018 to April 2023. The expert validity analysis was carried out by cross-sectional investigation combined with the results of the previous expert questionnaire to establish 12-lead ECG-based the rapid evaluate scale for pericardiectomy of tuberculous constrictive pericarditis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?