Background: Computed tomography images are easy to misjudge because of their complexity, especially images of solitary pulmonary nodules, of which diagnosis as benign or malignant is extremely important in lung cancer treatment. Therefore, there is an urgent need for a more effective strategy in lung cancer diagnosis. In our study, we aimed to externally validate and revise the Mayo model, and a new model was established.

Methods: A total of 1450 patients from three centers with solitary pulmonary nodules who underwent surgery were included in the study and were divided into training, internal validation, and external validation sets (n = 849, 365, and 236, respectively). External verification and recalibration of the Mayo model and establishment of new logistic regression model were performed on the training set. Overall performance of each model was evaluated using area under receiver operating characteristic curve (AUC). Finally, the model validation was completed on the validation data set.

Results: The AUC of the Mayo model on the training set was 0.653 (95% confidence interval [CI]: 0.613-0.694). After re-estimation of the coefficients of all covariates included in the original Mayo model, the revised Mayo model achieved an AUC of 0.671 (95% CI: 0.635-0.706). We then developed a new model that achieved a higher AUC of 0.891 (95% CI: 0.865-0.917). It had an AUC of 0.888 (95% CI: 0.842-0.934) on the internal validation set, which was significantly higher than that of the revised Mayo model (AUC: 0.577, 95% CI: 0.509-0.646) and the Mayo model (AUC: 0.609, 95% CI, 0.544-0.675) (P < 0.001). The AUC of the new model was 0.876 (95% CI: 0.831-0.920) on the external verification set, which was higher than the corresponding value of the Mayo model (AUC: 0.705, 95% CI: 0.639-0.772) and revised Mayo model (AUC: 0.706, 95% CI: 0.640-0.772) (P < 0.001). Then the prediction model was presented as a nomogram, which is easier to generalize.

Conclusions: After external verification and recalibration of the Mayo model, the results show that they are not suitable for the prediction of malignant pulmonary nodules in the Chinese population. Therefore, a new model was established by a backward stepwise process. The new model was constructed to rapidly discriminate benign from malignant pulmonary nodules, which could achieve accurate diagnosis of potential patients with lung cancer.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8318662PMC
http://dx.doi.org/10.1097/CM9.0000000000001507DOI Listing

Publication Analysis

Top Keywords

mayo model
28
model
13
solitary pulmonary
12
pulmonary nodules
12
computed tomography
8
lung cancer
8
internal validation
8
training set
8
revised mayo
8
model achieved
8

Similar Publications

There are few in vitro models available to study microglial physiology in a homeostatic context. Recent approaches include the human induced pluripotent stem cell model, but these can be challenging for large-scale assays and may lead to batch variability. To advance our understanding of microglial biology while enabling scalability for high-throughput assays, we developed an inducible immortalized murine microglial cell line using a tetracycline expression system.

View Article and Find Full Text PDF

The Anatomy of Gossip: Dissecting Dynamics and Impacts in Surgical Residency.

Surgery

January 2025

Department of Health Professions Education, MGH Institute for Health Professions Education, Boston, MA; Department of Surgery, Baylor Scott & White Health, Temple, TX. Electronic address: https://twitter.com/_baaw_.

Background: Gossip, defined by social scientists as "evaluative talk about an absent third party," is anecdotally pervasive yet poorly understood in surgical residency programs. Gossip is known to have both positive and negative impacts. This study sought to deconstruct the role of gossip in surgical residency and evaluate its impact through the lens of surgical residents.

View Article and Find Full Text PDF

Unlabelled: Ultrasound imaging plays an important role in the early detection and management of breast cancer. This study aimed to evaluate the imaging performance of a range of clinically-used breast ultrasound systems using a set of novel spherical lesion contrast-detail (C-D) and anechoic-target (A-T) phantoms.

Methods: C-D and A-T phantoms were imaged using a range of clinical breast ultrasound systems and imaging modes.

View Article and Find Full Text PDF

Variable relative biological effectiveness (RBE) of carbon radiotherapy may be calculated using several models, including the microdosimetric kinetic model (MKM), stochastic MKM (SMKM), repair-misrepair-fixation (RMF) model, and local effect model I (LEM), which have not been thoroughly compared. In this work, we compared how these four models handle carbon beam fragmentation, providing insight into where model differences arise. Monoenergetic and spread-out Bragg peak carbon beams incident on a water phantom were simulated using Monte Carlo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!