Stress fractures are overuse injuries of the bone characterized by a magnetic resonance imaging (MRI) finding of the fracture line with bone marrow edema. Clinical findings are tenderness and persistent pain. It is usually related to repetitive stresses. A 25-year-old woman was admitted with bilateral severe knee pain. She was in the postpartum period and the complaints started three days after the beginning of 2-h daily walk. The initial plain radiograph showed no abnormality, while MRI demonstrated bilateral incomplete fracture line at the proximal tibia. The patient had accompanying vitamin D deficiency and osteopenia, diagnosed with pregnancy-related osteopenia and stress fracture of bilateral proximal tibia. We advised cessation of weight bearing, resting, and supplementation of calcium and vitamin D. This report highlights that, in the postpartum period, persistent pain may indicate bone lesions such as stress fractures, particularly developing shortly after a vigorous physical activity. Detailed physical examination and further investigations are necessary to detect these fractures and risk factors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8343162PMC
http://dx.doi.org/10.5606/tftrd.2021.4947DOI Listing

Publication Analysis

Top Keywords

stress fracture
8
fracture bilateral
8
stress fractures
8
persistent pain
8
postpartum period
8
proximal tibia
8
postpartum stress
4
fracture
4
bilateral
4
bilateral tibia
4

Similar Publications

Modeling and analysis of explicit dynamics of foot landing.

Med Biol Eng Comput

January 2025

School of Medical Engineering, Department of Cardiology of The First Affiliated Hospital of Xinxiang Medical University, Xinxiang Medical University, Xinxiang, 453003, Henan, China.

The research aims to investigate the mechanical response of footfalls at different velocities to understand the mechanism of heel injury and provide a scientific basis for the prevention and treatment of heel fractures. A three-dimensional solid model of foot drop was constructed using anatomical structures segmented from medical CT scans, including bone, cartilage, ligaments, plantar fascia, and soft tissues, and the impact velocities of the foot were set to be 2 m/s, 4 m/s, 6 m/s, 8 m/s, and 10 m/s. Explicit kinetic analysis methods were used to investigate the mechanical response of the foot landing with different speeds to explore the damage mechanism of heel bone at different impact velocities.

View Article and Find Full Text PDF

Purpose: A finite element analysis was performed to simulate the biomechanical differences between anterior-posterior (AP) direction and posterior-anterior (PA) direction placement of two cannulated screws in Hoffa fractures.

Methods: Computed tomography images of an healthy male volunteer were used to simulate Letenneur Ⅰ, Ⅱa, Ⅱb, Ⅱc, Ⅲ Hoffa fractures, and two groups of screw internal fixation models were constructed. Two 6.

View Article and Find Full Text PDF

The accumulation of disposable face masks (DFMs) has become a significant threat to the environment due to extensive use during the COVID-19 pandemic. In this research, we investigated the degradation of DFMs after their disposal in landfills. We replicated the potential degradation process of DFMs, including exposure to sunlight before subjecting them to synthetic landfill leachate (LL).

View Article and Find Full Text PDF

High-Strength Anisotropic Fluorescent Hydrogel Based on Solvent Exchange for Patterning.

ACS Appl Mater Interfaces

January 2025

State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, P. R. China.

Aggregation-induced emission (AIE)-active fluorescent hydrogel materials have found extensive applications in soft robotics, wearable electronics, information encryption, and biomedicine. Nevertheless, it continues to be difficult to create hydrogels that are both highly luminescent and possess strong mechanical capabilities. This study introduces a combined approach of prestretching and solvent exchange to create anisotropic luminous hydrogels made of poly(methacrylic acid-methacrylamide).

View Article and Find Full Text PDF

Comparative finite element analysis: internal fixation plate versus intramedullary nail for neer type III-VI proximal humeral fractur.

J Orthop Surg Res

January 2025

Department of Orthopedics, Beijing Chaoyang Hospital, Capital Medical University, 8 Gongren Tiyuchang Nanlu, Chaoyang District, Beijing, 100020, China.

Background: Finite element analysis (FEA) could advance the understanding of fracture fixation and guide the choice of surgical treatment. This study aimed to compare two internal fixation methods in the treatment of displaced proximal humeral fracture (PHF) through FEA.

Methods: Three-dimensional FEA model based on the left shoulder joint of a 67-year-old female patient with PHFs and osteoporosis was adopted, in order to analyze the fixation effect and load stress distribution of internal fixation plates with open reduction and intramedullary nails without opening the fracture in the treatment of Neer III-VI PHF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!