A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of dermal exposure to N,N-dimethylacetamide in spray workers by combining personal exposure monitoring, biological monitoring, and glove permeation monitoring: A pilot study. | LitMetric

Objectives: We assessed dermal exposure to N,N-dimethylacetamide (DMAC) in a spray worker by utilizing a combination of personal exposure monitoring, biological monitoring, and glove permeation monitoring. We also determined the protective effects of chemical protective gloves (CPGs).

Methods: Surveys with and without CPG usage were performed on different days. In the survey with CPG usage, the worker had worn leather gloves over the CPG. Personal exposure monitoring and glove permeation monitoring were performed using 3M Organic Vapor Monitor 3500 and PERMEA-TEC Pads respectively. Urinary concentration of DMAC and its metabolites (N-methylacetamide [NMAC], N-hydroxymethyl-N-methylacetamide [DMAC-OH], S-(acetamidomethyl) mercapturic acid [AMMA]) were measured in the before-shift and end-of-shift samples collected from the worker.

Results: Personal exposure DMAC concentration in the survey with CPG usage (0.32 ppm) was twice that in the survey without CPG usage (0.15 ppm). However, urinary concentrations of DMAC-OH and AMMA in the end-of-shift samples in the survey with CPG usage (DMAC-OH, 0.74 mg/g creatinine; AMMA, 0.10 mg/g creatinine) were lower than those in the survey without CPG usage (DMAC-OH, 1.27 mg/g creatinine; AMMA, 0.24 mg/g creatinine). Urinary concentrations of DMAC and NMAC were below the limit of detection in all samples. DMAC concentrations in PERMEA-TEC Pads that were used in the surveys with and without CPG usage were in the range of 0.3-2.1 µg/sample and 16.4-1985.2 µg/sample respectively.

Conclusions: The combination of CPG usage and leather gloves was effective in preventing dermal exposure to DMAC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8361812PMC
http://dx.doi.org/10.1002/1348-9585.12265DOI Listing

Publication Analysis

Top Keywords

cpg usage
32
survey cpg
20
personal exposure
16
dermal exposure
12
exposure monitoring
12
monitoring glove
12
glove permeation
12
permeation monitoring
12
cpg
9
exposure nn-dimethylacetamide
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!