Intrauterine contraceptive devices (IUDs) distort the uterine cavity. We report 2 cases of endometrial molding demonstrated by hysterosalpingography (HSG) following removal of an IUD. Other processes may cause filling defects in the uterine cavity including inflammatory synechiae (Asherman's syndrome), tuberculosis, endometrial hyperplasia, and polyps. Whenever filling defects are seen, the history of IUD usage should be determined.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02932660DOI Listing

Publication Analysis

Top Keywords

intrauterine contraceptive
8
uterine cavity
8
filling defects
8
molding uterus
4
uterus intrauterine
4
contraceptive device
4
device removal
4
removal documentation
4
documentation hysterosalpingography
4
hysterosalpingography intrauterine
4

Similar Publications

Introduction: Despite increasing awareness on the prevention of Ureaplasma urealyticum (Uu) infection, the high-risk factors responsible for infection in female patients in China are yet to be determined.

Methodology: The study included 3043 Chinese women. Cervical secretion samples were collected for Uu identification.

View Article and Find Full Text PDF

Background: The use of intrauterine devices (IUDs) for contraception has increased in many countries. However, their application has some serious complications such as uterine perforation and injury to adjacent organs. The translocated IUD into the bladder is a very rare occurrence.

View Article and Find Full Text PDF

[Factors influencing pain during intrauterine device insertion].

Gynecol Obstet Fertil Senol

January 2025

Département de Gynécologie et Obstétrique, Hôpital Nord, Assistance Publique Hôpitaux de Marseille, Chemin des Bourrely, 13015 Marseille, France.

Objectives: Fear of pain during intrauterine device (IUD) insertion remains a barrier to its adoption. In the absence of consensus on an optimal pharmacological strategy, it is crucial to determine the factors influencing this pain to reassure and improve the patient experience.

Methods: It was a prospective study conducted in Provence-Alpes-Côte d'Azur between August 2023 and 2024, interviewing adult patients and healthcare professionals during consultations for IUD insertion.

View Article and Find Full Text PDF

Counsel patients that their Mirena IUD retains contraceptive effectiveness for extended use up to 8 years. The cumulative failure rate for years 6 through 8 was 0.68%, similar to reported rates for the first 5 years of use.

View Article and Find Full Text PDF

Introduction: The intrauterine device (IUD) inserted immediately after delivery is a safe and effective measure for preventing unplanned pregnancies. Despite exhibiting a higher expulsion rate compared with later insertions, it proves cost-effective due to the high rate of continuity of the method. There is still a gap in the literature regarding the optimal strategy for monitoring these patients, whether it should be through clinical examination, ultrasound or both.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!