A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance evaluation of ultrasonic transducer in a mist bioreactor by different nutrient media. | LitMetric

Performance evaluation of ultrasonic transducer in a mist bioreactor by different nutrient media.

Biotechnol Lett

Department of Food Technology, College of Aburaihan, University of Tehran, Tehran, Iran.

Published: October 2021

The mist bioreactor has been proved to have a higher performance relative to the liquid phase reactor. The water and conventional media (MS, ½MS, and B5) were tested in a mist bioreactor to evaluate the performance of the misting system. The physicochemical properties of liquids were measured at 0 (Fresh state) and when treated by ultrasonic system for 1 and 2 h. At a given airflow rate, the misting rate for different heights of various media was determined. The results demonstrated that the electrical conductivity of all media increased with the duration of sonication. The ultrasonic effect caused an increase in surface tension of MS and ½MS, while the pH of MS and ½MS reduced with ultrasonic treatment. The inverse trends were observed for water and B5 for these properties. The misting rate increased by increasing liquid height to a maximum value, then decreased to a minimum value at the highest height. For all liquids studied in this experiment, this maximum value of misting performed at height ranged between 3 and 4 cm. The maximum and minimum values of the ultrasonic misting rate belonged to MS ([Formula: see text]) at height 3 cm and B5 ([Formula: see text]) at height 1 cm, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10529-021-03168-0DOI Listing

Publication Analysis

Top Keywords

mist bioreactor
12
misting rate
12
[formula text]
8
text] height
8
ultrasonic
5
misting
5
height
5
performance evaluation
4
evaluation ultrasonic
4
ultrasonic transducer
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!