Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The detection of trypsin and its inhibitor is significantly important for both clinical diagnosis and disease treatment. Herein, we demonstrate a hydrogel-assisted paper-based lateral flow sensor for the detection of trypsin and its inhibitor for the first time. The gelatin hydrogel is hydrolyzed based on the gel-to-sol transition in the presence of trypsin, which results in the release of the trapped water molecules in the gelatin hydrogel. By placing one end of a pH indicator strip onto the hydrolyzed gelatin hydrogel, water is flowing along the pH indicator strip. However, in the absence of trypsin, water cannot flow along the pH indicator strip as the water molecules are trapped in the gelatin hydrogel. The detection limit of the system reaches as low as 1.0 × 10 mg/mL, and it is also applied to the quantitative detection of trypsin in human serum. In addition, the detection of a clinical drug aprotinin that is an inhibitor of trypsin is also successfully achieved. Noteworthy, only the gelatin hydrogel, pH indicator strip, and PS substrate are needed to fulfill the detection of trypsin without the need of other chemicals or reagents. Overall, we develop a particularly simple, elegant, robust, competitive, high-throughput, and low-cost approach for the rapid and label-free detection of trypsin and its inhibitor, which is very promising in the development of commercial products for sensing, diagnostic, and pharmaceutical applications. Besides, the hydrogel-assisted paper-based lateral flow sensor can also be employed to detect other analytes of interest by use of different stimuli-responsive hydrogel systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2021.113548 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!