Microwave-induced thermoacoustic imaging (MTAI) has been widely used in biomedical science, and has the potential as an auxiliary measure for clinical diagnosis and treatment. Recently, there are increasing interests in using ultrashort microwave-pumped thermoacoustic imaging techniques to obtain high-efficiency, high-resolution images. However, the traditional imaging system can only provide uniform radiation in a relatively small area, which limits their large field of view in clinical applications (such as whole-breast imaging, brain imaging). To address this problem, we propose an ultrashort pulse microwave thermoacoustic imaging device with a large size aperture antenna. The system can provide a microwave radiation area of 40 cm × 27 cm and a uniform imaging view of 14 cm × 14 cm. With 7 cm imaging depth and a 290 μm resolution. The practical feasibility of the system for breast tumor screening is tested in phantoms with different shapes and in an ex vivo human breast tumor which is embedded in the excised breast of an ewe (π × 5 cm × 5 cm). The tumor can be identified with a contrast of about 1:2. The results demonstrate that the dedicated MTAI system with the uniform large field of view, high imaging resolution, and large imaging depth have the potential for clinical routine breast screening.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2021.3104137DOI Listing

Publication Analysis

Top Keywords

thermoacoustic imaging
16
imaging
11
large size
8
size aperture
8
aperture antenna
8
tumor screening
8
system provide
8
large field
8
field view
8
imaging depth
8

Similar Publications

Existing TAI systems mostly use metal wires to calibrate their spatial resolution. However, research on the imaging mechanism of the metal wire and the setting of the wire parameters that can affect the system's spatial resolution is not sufficient in this context. In general, there is a lack of understanding of the factors affecting spatial resolution.

View Article and Find Full Text PDF

A Review on Ultrasound-based Methods to Image the Distribution of Magnetic Nanoparticles in Biomedical Applications.

Ultrasound Med Biol

February 2025

Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Professorship for Al-Controlled Nanomaterials (KINAM), Universitätsklinikum Erlangen, Erlangen, Germany.

Magnetic nanoparticles (MNPs) have gained significant attention in biomedical engineering and imaging applications due to their unique magnetic and mechanical properties. With their high magnetization and small size, MNPs serve as excitation sources for magnetically heating to destroy tumors (magnetic hyperthermia) and magnetically controlled drug carriers in magnetic drug targeting. However, effectively visualizing the distribution of MNPs during research or potential clinical use with low-cost modalities remains a critical challenge.

View Article and Find Full Text PDF

Microwave-induced thermoacoustic tomography (MITAT) holds significant promise in biomedical applications. It creates images using ultrasonic sensors to detect thermoacoustic signals induced by microwaves. The key to generating thermoacoustic signals that accurately reflect the fact is to achieve sufficient and uniform microwave power absorption of the testing target, which is closely tied to the microwave illumination provided by the antenna.

View Article and Find Full Text PDF

Microwave-induced thermoacoustic imaging (M-TAI) allows the visualization of macroscopic and microscopic structures of bio-tissues. However, it suffers from severe inherent artifacts that might misguide the subsequent diagnostics and treatments of diseases. To overcome this limitation, we propose an optimized excitation strategy.

View Article and Find Full Text PDF

Background: When applied to thermoacoustic imaging (TAI), the delay-and-sum (DAS) algorithm produces strong sidelobes due to its disadvantages of uniform aperture weighting. As a result, the quality of TAI images recovered by DAS is often severely degraded by strong non-coherent clutter, which restricts the development and application of TAI.

Purpose: To address this issue, we propose an adaptive complementary neighboring sub-aperture (NSA) beamforming algorithm for TAI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!