A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A rapid nucleic acid concentration measurement system with large field of view for a droplet digital PCR microfluidic chip. | LitMetric

Droplet digital polymerase chain reaction (ddPCR) is an effective technique, with unparalleled sensitivity, for the absolute quantification of target nucleic acids. However, current commercial ddPCR devices for detecting the gene chip are time consuming due to complex image stitching. To address this issue, we propose a universal concentration determination system and realize one-time gene chip imaging with high resolution. All the functional units are controlled by self-developed software using the PyQt5 module in Python. Without stitching technology, images of the ddPCR chip (28 mm × 18 mm) containing 20 000 independent 0.81 nL micro chambers can be obtained in less than 15 seconds, which saves about 165 seconds. A white laser light source (2 mW cm) was employed as a substitute for the mercury lamp. Its wavelength matches well with typical fluorescent dyes (, HEX, ROX and Cy5), and thus it can strengthen the fluorescence intensity for weak signals. The results also demonstrated that the correlation coefficient for the measured concentration and theoretical value was above 99%, by testing the ddPCR products with COVID-19 virus. Such a system can greatly reduce the time required for image acquisition and DNA concentration determination, and thus is able to speed up the lab-to-application process for ddPCR technology.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d1lc00532dDOI Listing

Publication Analysis

Top Keywords

droplet digital
8
gene chip
8
concentration determination
8
ddpcr
5
rapid nucleic
4
nucleic acid
4
concentration
4
acid concentration
4
concentration measurement
4
measurement system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!