Time Evolution of the Skin-Electrode Interface Impedance under Different Skin Treatments.

Sensors (Basel)

Department of Bioengineering, 240 Skirkanich Hall, University of Pennsylvania, 210 S. 33rd Street, Philadelphia, PA 19104, USA.

Published: July 2021

A low and stable impedance at the skin-electrode interface is key to high-fidelity acquisition of biosignals, both acutely and in the long term. However, recording quality is highly variable due to the complex nature of human skin. Here, we present an experimental and modeling framework to investigate the interfacial impedance behavior, and describe how skin interventions affect its stability over time. To illustrate this approach, we report experimental measurements on the skin-electrode impedance using pre-gelled, clinical-grade electrodes in healthy human subjects recorded over 24 h following four skin treatments: (i) mechanical abrasion, (ii) chemical exfoliation, (iii) microporation, and (iv) no treatment. In the immediate post-treatment period, mechanical abrasion yields the lowest initial impedance, whereas the other treatments provide modest improvement compared to untreated skin. After 24 h, however, the impedance becomes more uniform across all groups (<20 kΩ at 10 Hz). The impedance data are fitted with an equivalent circuit model of the complete skin-electrode interface, clearly identifying skin-level versus electrode-level contributions to the overall impedance. Using this model, we systematically investigate how time and treatment affect the impedance response, and show that removal of the superficial epidermal layers is essential to achieving a low, long-term stable interface impedance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8348734PMC
http://dx.doi.org/10.3390/s21155210DOI Listing

Publication Analysis

Top Keywords

skin-electrode interface
8
skin treatments
8
mechanical abrasion
8
impedance
6
skin
5
time evolution
4
evolution skin-electrode
4
interface impedance
4
impedance skin
4
treatments low
4

Similar Publications

Motion Artifacts in Dynamic EEG Recordings: Experimental Observations, Electrical Modelling, and Design Considerations.

Sensors (Basel)

September 2024

Laboratory of Neuromuscular System and Rehabilitation Engineering, Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Turin, Italy.

Despite the progress in the development of innovative EEG acquisition systems, their use in dynamic applications is still limited by motion artifacts compromising the interpretation of the collected signals. Therefore, extensive research on the genesis of motion artifacts in EEG recordings is still needed to optimize existing technologies, shedding light on possible solutions to overcome the current limitations. We identified three potential sources of motion artifacts occurring at three different levels of a traditional biopotential acquisition chain: the skin-electrode interface, the connecting cables between the detection and the acquisition systems, and the electrode-amplifier system.

View Article and Find Full Text PDF

Self-Healing and Shear-Stiffening Electrodes for Wearable Biopotential Sensing and Gesture Recognition.

ACS Sens

October 2024

School of Precision Instrument and Optoelectronics Engineering, Tianjin University, 92 Weijin Road, Tianjin 300072, China.

The achievement of flexible skin electrodes for dynamic monitoring of biopotential is one of the challenging issues in flexible electronics due to the interference of large acceleration and heavy sweat that influence the stability of skin-electrode interfaces. This work presents materials and techniques to achieve self-healing and shear-stiffening electrodes and an associated flexible system that can be used for multichannel biopotential measurement on the skin. The electrode that is based on a composite of silver (Ag) flakes, Ag nanowires, and polyborosiloxane offers an electrical conductivity of 9.

View Article and Find Full Text PDF

Wearable long-term monitoring applications are becoming more and more popular in both the consumer and the medical market. In wearable ECG monitoring, the data quality depends on the properties of the electrodes and on how they interface with the skin. Dry electrodes do not require any action from the user.

View Article and Find Full Text PDF

Electrooculography (EOG) serves as a widely employed technique for tracking saccadic eye movements in a diverse array of applications. These encompass the identification of various medical conditions and the development of interfaces facilitating human-computer interaction. Nonetheless, EOG signals are often met with skepticism due to the presence of multiple sources of noise interference.

View Article and Find Full Text PDF

Stretchable Gold Nanomembrane Electrode with Ionic Hydrogel Skin-Adhesive Properties.

Polymers (Basel)

September 2023

Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.

Skin has a dynamic surface and offers essential information through biological signals originating from internal organs, blood vessels, and muscles. Soft and stretchable bioelectronics can be used in wearable machines for long-term stability and to continuously obtain distinct bio-signals in conjunction with repeated expansion and contraction with physical activities. While monitoring bio-signals, the electrode and skin must be firmly attached for high signal quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!