A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of LECO FP-228 "nitrogen determinator" with AOAC copper catalyst Kjeldahl method for crude protein. | LitMetric

Comparison of LECO FP-228 "nitrogen determinator" with AOAC copper catalyst Kjeldahl method for crude protein.

J Assoc Off Anal Chem

University of Missouri, Experiment Station Chemical Laboratories, Columbia 65211.

Published: March 1988

The LECO FP-228 "Nitrogen Determinator" was compared with the AOAC copper catalyst Kjeldahl method, 7.033-7.037, for the determination of crude protein in feed materials. The completely microprocessor-controlled instrument determines nitrogen by measuring the nitrogen gas following combustion of the sample; it was easy to operate and broadly applicable. A wide variety of feed materials of various nitrogen levels were analyzed in one mixed sequence. Results were precise, accurate, and rapid. Analysis time for one sample was approximately 3 min. Fourteen samples containing 2.5-15.5% N were selected for study and consisted of meals, grains, forages, and standard organic materials. The overall mean for the 14 samples by the LECO combustion method was 8.61% N compared with an overall mean of 8.58% N for the AOAC Kjeldahl method. Within-sample standard deviations for the LECO combustion method ranged from 0.013 to 0.052% N with a pooled standard deviation (SD) of 0.033% N for the 14 samples. Standard deviations for the AOAC Kjeldahl method ranged from 0.006 to 0.035% N with a pooled SD of 0.022% N. Combined average recovery of nitrogen from tryptophan, lysine-HCl, and EDTA determined by the LECO combustion method was 99.94% compared to 99.88% determined by the AOAC Kjeldahl method.

Download full-text PDF

Source

Publication Analysis

Top Keywords

kjeldahl method
20
leco combustion
12
combustion method
12
aoac kjeldahl
12
leco fp-228
8
fp-228 "nitrogen
8
"nitrogen determinator"
8
aoac copper
8
copper catalyst
8
catalyst kjeldahl
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!