Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years.

Pan Afr Med J

Department of Orthopaedic and Trauma Surgery, Ibn Tofail Hospital, Mohammed VI University Hospital Center, Abdelouahab Derraq Street, PB 40000, Marrakesh, Morocco.

Published: August 2021

Introduction: the dynamic condylar screw (DCS) plate is an angular stable fixation (95°) system for distal femur fractures that allows for the ability to apply compression across the femoral condyles. The aim of this study was to evaluate our experience treating distal femur fractures with this device and give the long-term outcome.

Methods: a retrospective study was undertaken in our institution during the period from January 2002 to December 2016. A total number of 240 patients with distal femur fractures were managed using DCS plate system and included in the study. The mean follow-up period was 33 months (26 - 62 months). Clinico-radiological progression of fracture union as well as the functional outcome was studied.

Results: most of the fractures were closed injuries in young male patients resulting from traffic accidents. The average time to union was 12.6 weeks (range 11 - 23). Eight patients (3.3%) suffered superficial infection. Five patients (2.1%) developed deep venous thrombosis. Delayed union was observed in nine cases (3.7%) and non union in six cases (2.5%). At final follow-up, the mean range of motion (ROM) of knee was 115.7° (100°-148°). The mean Knee Society Score (KSS) was 84.5 (59 - 94) and the mean Lysholm score was 88.6 (range, 61 - 96), translating to good clinical results.

Conclusion: our study conclusively establishes that excellent functional outcome can be achieved with DCS plate inserted with skilled surgical technique in distal femur fractures including the ones that are communited or occurring in osteoporotic bone with a negligible complication rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8308866PMC
http://dx.doi.org/10.11604/pamj.2021.38.363.27524DOI Listing

Publication Analysis

Top Keywords

dcs plate
16
distal femur
16
femur fractures
16
dynamic condylar
8
condylar screw
8
screw dcs
8
plate system
8
functional outcome
8
fractures
6
outcomes distal
4

Similar Publications

Gene expression of Decompression Sickness-resistant rats through a miRnome/transcriptome crossed approach.

Commun Biol

October 2024

Univ Brest, ORPHY's Laboratory, 6 Av Le Gorgeu, CS93837, F-29238, Brest, Cedex, France.

Article Synopsis
  • Researchers studied why some individuals are more prone to decompression sickness (DCS) than others by breeding rats with much higher resistance to DCS than the average rat.
  • They analyzed the genetic expression differences between these resistant rats and a standard rat strain using advanced techniques to uncover important genes and their functions.
  • The study found that pathways related to inflammation and other biological processes play significant roles in how DCS develops.
View Article and Find Full Text PDF

Differentiation, maturation, and collection of THP-1-derived dendritic cells based on a PEG hydrogel culture platform.

Biotechnol Lett

April 2024

Department of Agriculture, Forestry and Bioresources, Seoul National University, Seoul, 08826, Republic of Korea.

Purpose: Dendritic cell (DC) is a spearhead responsible for immune response and surrounded by extracellular matrix in three-dimensional (3D) tissue. Nevertheless, conventional DC culture has relied on suspension or two-dimensional (2D) tissue culture plate (TCP)-based culture system. This culture condition often fails to recapitulate the physiological behavior of DC in real tissue.

View Article and Find Full Text PDF

Second-generation headless compression screws (HCSs) are commonly used for the fixation of small bones and articular fractures. However, there is a lack of biomechanical data regarding the application of such screws to radial head fractures. This study evaluated the mechanical properties of the fixation of radial head fractures using a single oblique HCS compared with those obtained using a standard locking radial head plate (LRHP) construct and a double cortical screw (DCS) construct.

View Article and Find Full Text PDF

Fluid shear stress enhances dendritic cell activation.

Immunobiology

November 2023

Department of Biomedical Engineering, Vanderbilt University, 2414 Highland Ave, Nashville, TN 37212, United States. Electronic address:

Ex vivo activation of dendritic cells (DCs) has been widely explored for targeted therapies, although these treatments remain expensive. Reducing treatment costs while enhancing cell activation could help to make immunotherapies more accessible. Cells can be activated by both internal and external forces including fluid shear stress (FSS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!