A cardiovascular stent design optimization method is proposed with application to a pediatric balloon-expandable prosthetic heart valve. The prosthetic valved conduit may be expanded to a larger permanent diameter via subsequent transcatheter balloon dilation procedures. While multiple expandable prosthetic heart valves are currently at different stages of development, this work is focused on one particular design in which a stent is situated inside of an expandable polymeric valved conduit. Since the valve and conduit must be joined with a robust manufacturing technique, a polymeric glue layer is inserted between the two, which results in radial retraction of the valved region after expansion. Design of an appropriate stent is proposed to counteract this phenomenon and maintain the desired permanent diameter throughout the device after a single non-compliant balloon dilation procedure. The finite element method is used to compute performance metrics related to the permanent expansion diameter and required radial force. Additionally, failure due not only to high cycle fatigue but also due to ductile fracture is incorporated into the design study through the use of an existing ductile fracture criterion for metals. Surrogate models are constructed with the results of the high fidelity simulations and are subsequently used to numerically obtain a set of Pareto-optimal stent designs. Finally, a single design is identified by optimizing a normalized aggregate objective function with equal weighting of all design objectives.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8336925 | PMC |
http://dx.doi.org/10.1016/j.matdes.2021.109977 | DOI Listing |
Eur Heart J Case Rep
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka 589-8511, Japan.
Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.
View Article and Find Full Text PDFMicrosc Res Tech
January 2025
Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
Effect of different root canal irrigation regimes microbubble emulsion (MBE) via riboflavin photosensitizer (RFP), cerium oxide (CeO) nanoparticles (NPs), and Nd: YAP laser on antibacterial efficiency, microhardness (MH), smear layer (SL) removal efficacy, and push-out bond strength (PBS) of AH plus sealer to canal dentin. Sixty single-rooted teeth were selected, disinfected, and categorized into four groups based on the type of disinfection. Following disinfection, a pair of samples were randomly selected and visualized under scanning electron microscope (SEM) for SL evaluation.
View Article and Find Full Text PDFBackground: Coronary heart disease (CHD) and depression frequently co-occur, significantly impacting patient outcomes. However, comprehensive health status assessment tools for this complex population are lacking. This study aimed to develop and validate an explainable machine learning model to evaluate overall health status in patients with comorbid CHD and depression.
View Article and Find Full Text PDFJMIR Res Protoc
January 2025
School of Exercise and Nutrition Sciences, Institute for Physical Activity and Nutrition, Deakin University, Burwood, Australia.
Background: Heart failure (HF) is a chronic, progressive condition where the heart cannot pump enough blood to meet the body's needs. In addition to the daily challenges that HF poses, acute exacerbations can lead to costly hospitalizations and increased mortality. High health care costs and the burden of HF have led to the emerging application of new technologies to support people living with HF to stay well while living in the community.
View Article and Find Full Text PDFActa Bioeng Biomech
June 2024
1Department of Biomedical Engineering, Hefei University of Technology, Hefei, People's Republic of China.
: The utilization of intra-aortic balloon pump (IABP) and Impella has been suggested as means of left ventricular unloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) patients. This study aimed to assess the local hemodynamic alterations in VA-ECMO patients through simulation analyses. : In this study, a 0D-3D multiscale model was developed, wherein resistance conditions were employed to define the flow-pressure relationship.