Nix Pro Color Sensor provides comparable color measurements to HunterLab colorimeter for fresh beef.

J Food Sci Technol

Center for Meat Safety & Quality, Department of Animal Sciences, Colorado State University, 1171 Campus Delivery, Fort Collins, CO 80523-1171 USA.

Published: September 2021

The HunterLab MiniScan (HunterLab) colorimeter is used in meat quality research worldwide for measuring meat color; however, the Nix Pro Color Sensor (Nix) could be a less expensive alternative that is easier to operate. Therefore, the objective of this study was to compare the two colorimeters to objectively evaluate fresh beef color. muscle from one side of A maturity beef carcasses ( = 200) was evaluated using both the HunterLab (3 technical replicate scans) and Nix (3, 5, 7, and 9 technical replicate scans) colorimeters. The correlation between the HunterLab and Nix for (lightness), (redness), and (yellowness) values ranged between r = 0.80 to 0.85 and the Bland Altman Limits of Agreement analysis indicated good agreement between the Nix and HunterLab colorimeters for all the color parameters. These results indicated that the Nix colorimeter could be a viable alternative for HunterLab colorimeters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8292471PMC
http://dx.doi.org/10.1007/s13197-021-05077-6DOI Listing

Publication Analysis

Top Keywords

nix pro
8
pro color
8
color sensor
8
hunterlab colorimeter
8
fresh beef
8
technical replicate
8
replicate scans
8
hunterlab colorimeters
8
nix
7
hunterlab
7

Similar Publications

Novel low-cost portable spectrophotometers could be an alternative to traditional spectrophotometers and calibrated RGB cameras by offering lower prices and convenient measurements but retaining high colorimetric accuracy. This study evaluated the colorimetric accuracy of low-cost, portable spectrophotometers on the established color calibration target-RAL Design System Plus (RAL+). Four spectrophotometers with a listed price between USD 100-1200 (Nix Spectro 2, Spectro 1 Pro, ColorReader, and Pico) and a smartphone RGB camera were tested on a representative subset of 183 RAL+ colors.

View Article and Find Full Text PDF

Aim: The present study aimed to investigate the effects of a single bout of resistance exercise on mitophagy in human skeletal muscle (SkM).

Methods: Eight healthy men were recruited to complete an acute bout of one-leg resistance exercise. SkM biopsies were obtained one hour after exercise in the resting leg (Rest-leg) and the contracting leg (Ex-leg).

View Article and Find Full Text PDF

The colour of seafood flesh is often not homogenous, hence measurement of colour requires repeat measurements to obtain a representative average. The aim of this study was to determine the optimal number of repeat colour measurements required for three different devices [machine vision (digital image using camera, and computer processing); Nix Pro; Minolta CR400 colorimeter] when measuring three species of seafood (Atlantic salmon, , = 8; rockling, , = 8; banana prawns, , = 105) for raw and cooked samples. Two methods of analysis for number of repeat measurements required were compared.

View Article and Find Full Text PDF

Comparative study on measurements of radiochromic films using portable colorimeters.

Sci Rep

February 2024

School of Medicine, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima, 734-8553, Japan.

The recently proposed method for on-site radiation dosimetry by a combination of radiochromic film and portable colorimeter was tested for six combinations of two popular Gafchromic films (EBT3 and EBT-XD) and three commercially available portable colorimeters (nix pro2, nix spectro2 and Spectro1 Pro; abbreviated to "NixP", "NixS" and "SpoP", respectively). EBT3 and EBT-XD were irradiated with X-rays (160 kV, 6.3 mA) up to 40 Gy and 80 Gy, respectively, and the radiation-induced color levels of RGB and CMYK components were measured with the three colorimeters.

View Article and Find Full Text PDF

Purpose: Stereotactic body radiation therapy (SBRT) is increasingly used as a definitive treatment option for patients with prostate adenocarcinoma. The aim of this study was to assess the late toxicity, patient-reported quality of life outcomes, and biochemical recurrence rates after prostate SBRT with simultaneous integrated boost (SIB) targeting lesions defined by magnetic resonance imaging (MRI).

Methods And Materials: Patients were eligible if they had biopsy-proven low- or intermediate-risk prostate adenocarcinoma, one or more focal lesions on MRI, and an MRI-defined total prostate volume of <120 mL.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!